Development of an ion beam detector for the atomic beam probe diagnostic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F18%3A10389472" target="_blank" >RIV/00216208:11320/18:10389472 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389021:_____/18:00498182 RIV/68407700:21340/18:00327318
Výsledek na webu
<a href="https://doi.org/10.1063/1.5044529" target="_blank" >https://doi.org/10.1063/1.5044529</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5044529" target="_blank" >10.1063/1.5044529</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of an ion beam detector for the atomic beam probe diagnostic
Popis výsledku v původním jazyce
The atomic beam probe diagnostic concept aims at measuring the edge magnetic field and through that edge current distribution in fusion plasmas by observing trajectories of an ion beam stemming from a diagnostic neutral beam. The diagnostic potentially has microsecond scale time resolution and can thus prove to be a powerful option to study fast changes in the edge plasma. A test detector has been installed on the COMPASS tokamak as an extension of the existing lithium beam diagnostic system. It employs a relatively simple concept of an array of conductive detection plates measuring the incident ion current, which is then amplified and converted to a voltage signal. The aim of the test detector is to experimentally examine the idea of the diagnostic and provide background data for design and installation of a final detector. Also, a numerical code based on the CUDA parallel computing platform has been developed for modeling lithium ion trajectories in the given COMPASS plasma discharges. We present the developments of the detector design and test measurements of the diagnostic performed both in a laboratory beam system and on the COMPASS tokamak. Published by AIP Publishing.
Název v anglickém jazyce
Development of an ion beam detector for the atomic beam probe diagnostic
Popis výsledku anglicky
The atomic beam probe diagnostic concept aims at measuring the edge magnetic field and through that edge current distribution in fusion plasmas by observing trajectories of an ion beam stemming from a diagnostic neutral beam. The diagnostic potentially has microsecond scale time resolution and can thus prove to be a powerful option to study fast changes in the edge plasma. A test detector has been installed on the COMPASS tokamak as an extension of the existing lithium beam diagnostic system. It employs a relatively simple concept of an array of conductive detection plates measuring the incident ion current, which is then amplified and converted to a voltage signal. The aim of the test detector is to experimentally examine the idea of the diagnostic and provide background data for design and installation of a final detector. Also, a numerical code based on the CUDA parallel computing platform has been developed for modeling lithium ion trajectories in the given COMPASS plasma discharges. We present the developments of the detector design and test measurements of the diagnostic performed both in a laboratory beam system and on the COMPASS tokamak. Published by AIP Publishing.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000451735700032
EID výsledku v databázi Scopus
2-s2.0-85056787972