Preliminary results on the 233U capture cross section and alpha ratio measured at n_TOF (CERN) with the fission tagging technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F19%3A10405014" target="_blank" >RIV/00216208:11320/19:10405014 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1051/epjconf/201921103007" target="_blank" >https://doi.org/10.1051/epjconf/201921103007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201921103007" target="_blank" >10.1051/epjconf/201921103007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preliminary results on the 233U capture cross section and alpha ratio measured at n_TOF (CERN) with the fission tagging technique
Popis výsledku v původním jazyce
U-233 is of key importance among the fissile nuclei in the Th-U fuel cycle. A particularity of U-233 is its small neutron capture cross-section, which is on average about one order of magnitude lower than the fission cross-section. The accuracy in the measurement of the U-233 capture crosssection depends crucially on an efficient capture-fission discrimination, thus a combined set-up of fission and y-detectors is needed. A measurement of the U-233 capture cross-section and capture-to -fission ratio was performed at the CERN n_TOF facility. The Total Absorption Calorimeter (TAC) of n_TOF was employed as y-detector coupled with a novel compact ionization chamber as fission detector. A brief description of the experimental set-up will be given, and essential parts of the analysis procedure as well as the preliminary response of the set-up to capture are presented and discussed.
Název v anglickém jazyce
Preliminary results on the 233U capture cross section and alpha ratio measured at n_TOF (CERN) with the fission tagging technique
Popis výsledku anglicky
U-233 is of key importance among the fissile nuclei in the Th-U fuel cycle. A particularity of U-233 is its small neutron capture cross-section, which is on average about one order of magnitude lower than the fission cross-section. The accuracy in the measurement of the U-233 capture crosssection depends crucially on an efficient capture-fission discrimination, thus a combined set-up of fission and y-detectors is needed. A measurement of the U-233 capture cross-section and capture-to -fission ratio was performed at the CERN n_TOF facility. The Total Absorption Calorimeter (TAC) of n_TOF was employed as y-detector coupled with a novel compact ionization chamber as fission detector. A brief description of the experimental set-up will be given, and essential parts of the analysis procedure as well as the preliminary response of the set-up to capture are presented and discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LTT17018" target="_blank" >LTT17018: Získávání nových poznatků o mikrosvětě v infrastruktuře CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences [online]
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
E D P SCIENCES
Místo vydání
CEDEX A
Místo konání akce
Aix en Provence
Datum konání akce
8. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000501343100013