A high precision calibration of the nonlinear energy response at Daya Bay
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F19%3A10406939" target="_blank" >RIV/00216208:11320/19:10406939 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ajy1Sg8g2N" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ajy1Sg8g2N</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2019.06.031" target="_blank" >10.1016/j.nima.2019.06.031</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A high precision calibration of the nonlinear energy response at Daya Bay
Popis výsledku v původním jazyce
A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment's antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by.. calibration points from deployed and naturally occurring radioactive sources, the.. spectrum from B-12 decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.
Název v anglickém jazyce
A high precision calibration of the nonlinear energy response at Daya Bay
Popis výsledku anglicky
A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment's antineutrino detectors is presented in detail. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by.. calibration points from deployed and naturally occurring radioactive sources, the.. spectrum from B-12 decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LTT17021" target="_blank" >LTT17021: Reaktorové neutrinové experimenty Daya Bay a JUNO</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
940
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
230-242
Kód UT WoS článku
000475349600034
EID výsledku v databázi Scopus
2-s2.0-85067607188