Modification of a SERS-active Ag surface to promote adsorption of charged analytes: effect of Cu2+ions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F21%3A10438601" target="_blank" >RIV/00216208:11320/21:10438601 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=OLtHQqnxec" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=OLtHQqnxec</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3762/bjnano.12.67" target="_blank" >10.3762/bjnano.12.67</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modification of a SERS-active Ag surface to promote adsorption of charged analytes: effect of Cu2+ions
Popis výsledku v původním jazyce
This work studies the impact of the electrostatic interaction between analyte molecules and silver nanoparticles (Ag NPs) on the intensity of surface-enhanced Raman scattering (SERS). For this, we fabricated nanostructured plasmonic films by immobilization of Ag NPs on glass plates and functionalized them by a set of differently charged hydrophilic thiols (sodium 2-mercaptoethyl sulfonate, mercaptopropionic acid, 2-mercaptoethanol, 2-(dimethylamino)ethanethiol hydrochloride, and thiocholine) to vary the surface charge of the SERS substrate. We used two oppositely charged porphyrins, cationic copper(II) tetrakis(4-N-methylpyridyl) porphine (CuTMpyP4) and anionic copper(II) 5,10,15,20-tetrakis(4-sulfonatophenyl)porphine (CuTSPP4), with equal charge value and similar structure as model analytes to probe the SERS signal. Our results indicate that the SERS spectrum intensity strongly, up to complete signal disappearance, correlates with the surface charge of the substrate, which tends to be negative. Using the data obtained and our model SERS system, we analyzed the modification of the Ag surface by different reagents (lithium chloride, polyethylenimine, polyhexamethylene guanidine, and multicharged metal ions). Finally, all those surface modifications were tested using a negatively charged oligonucleotide labeled with Black Hole Quencher dye. Only the addition of copper ions into the analyte solution yielded a good SERS signal. Considering the strong interaction of copper ions with the oligonucleotide molecules, we suppose that inversion of the analyte charge played a key role in this case, instead of a change of charge of the substrate surface. Changing the charge of analytes could be a promising way to get clear SERS spectra of negatively charged molecules on Ag SERSactive supports.
Název v anglickém jazyce
Modification of a SERS-active Ag surface to promote adsorption of charged analytes: effect of Cu2+ions
Popis výsledku anglicky
This work studies the impact of the electrostatic interaction between analyte molecules and silver nanoparticles (Ag NPs) on the intensity of surface-enhanced Raman scattering (SERS). For this, we fabricated nanostructured plasmonic films by immobilization of Ag NPs on glass plates and functionalized them by a set of differently charged hydrophilic thiols (sodium 2-mercaptoethyl sulfonate, mercaptopropionic acid, 2-mercaptoethanol, 2-(dimethylamino)ethanethiol hydrochloride, and thiocholine) to vary the surface charge of the SERS substrate. We used two oppositely charged porphyrins, cationic copper(II) tetrakis(4-N-methylpyridyl) porphine (CuTMpyP4) and anionic copper(II) 5,10,15,20-tetrakis(4-sulfonatophenyl)porphine (CuTSPP4), with equal charge value and similar structure as model analytes to probe the SERS signal. Our results indicate that the SERS spectrum intensity strongly, up to complete signal disappearance, correlates with the surface charge of the substrate, which tends to be negative. Using the data obtained and our model SERS system, we analyzed the modification of the Ag surface by different reagents (lithium chloride, polyethylenimine, polyhexamethylene guanidine, and multicharged metal ions). Finally, all those surface modifications were tested using a negatively charged oligonucleotide labeled with Black Hole Quencher dye. Only the addition of copper ions into the analyte solution yielded a good SERS signal. Considering the strong interaction of copper ions with the oligonucleotide molecules, we suppose that inversion of the analyte charge played a key role in this case, instead of a change of charge of the substrate surface. Changing the charge of analytes could be a promising way to get clear SERS spectra of negatively charged molecules on Ag SERSactive supports.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-10897S" target="_blank" >GA18-10897S: Nové přístupy v povrchem zesílené optické spektroskopii pro vysoce citlivý a specifický biosenzing</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Beilstein Journal of Nanotechnology [online]
ISSN
2190-4286
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
16 August
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
11
Strana od-do
902-912
Kód UT WoS článku
000686075500001
EID výsledku v databázi Scopus
2-s2.0-85115775645