Measurement of the distribution of Bi-207 depositions on calibration sources for SuperNEMO
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F21%3A10439717" target="_blank" >RIV/00216208:11320/21:10439717 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/21:00350759
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=wN2GZhZdoP" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=wN2GZhZdoP</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/16/07/T07012" target="_blank" >10.1088/1748-0221/16/07/T07012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of the distribution of Bi-207 depositions on calibration sources for SuperNEMO
Popis výsledku v původním jazyce
The SuperNEMO experiment will search for neutrinoless double-beta decay (0 upsilon beta beta), and study the Standard-Model double-beta decay process (2 upsilon beta beta). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta (beta beta) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of Bi-207 within a frame assembly. The quality of these sources, which depends upon the entire Bi-207 droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of Bi-207 droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.
Název v anglickém jazyce
Measurement of the distribution of Bi-207 depositions on calibration sources for SuperNEMO
Popis výsledku anglicky
The SuperNEMO experiment will search for neutrinoless double-beta decay (0 upsilon beta beta), and study the Standard-Model double-beta decay process (2 upsilon beta beta). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta (beta beta) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of Bi-207 within a frame assembly. The quality of these sources, which depends upon the entire Bi-207 droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of Bi-207 droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10300 - Physical sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018107" target="_blank" >LM2018107: Podzemní laboratoř LSM - účast České republiky</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation [online]
ISSN
1748-0221
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
18
Strana od-do
T07012
Kód UT WoS článku
000694724700003
EID výsledku v databázi Scopus
2-s2.0-85112053859