Silicon Drift Detectors for the Measurement and Reconstruction of Beta Spectra
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F24%3A10493800" target="_blank" >RIV/00216208:11320/24:10493800 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Dpum~uuf7O" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Dpum~uuf7O</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s24248202" target="_blank" >10.3390/s24248202</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Silicon Drift Detectors for the Measurement and Reconstruction of Beta Spectra
Popis výsledku v původním jazyce
The ASPECT-BET project, or An sdd-SPECTrometer for BETa decay studies, aims to develop a novel technique for the precise measurement of forbidden beta spectra in the 10 keV-1 MeV range. This technique employs a Silicon Drift Detector (SDD) as the main spectrometer with the option of a veto system to reject events exhibiting only partial energy deposition in the SDD. A precise understanding of the spectrometer's response to electrons is crucial for accurately reconstructing the theoretical shape of the beta spectrum. To compute this response, GEANT4 simulations optimized for low-energy electron interactions are used and validated with a custom-made electron gun. In this article we present the performance of these simulations in reconstructing the electron spectra measured with SDDs of a 109Cd monochromatic source, both in vacuum and in air. The allowed beta spectrum of a 14C source was also measured and analyzed, proving that this system is suitable for the application in ASPECT-BET.
Název v anglickém jazyce
Silicon Drift Detectors for the Measurement and Reconstruction of Beta Spectra
Popis výsledku anglicky
The ASPECT-BET project, or An sdd-SPECTrometer for BETa decay studies, aims to develop a novel technique for the precise measurement of forbidden beta spectra in the 10 keV-1 MeV range. This technique employs a Silicon Drift Detector (SDD) as the main spectrometer with the option of a veto system to reject events exhibiting only partial energy deposition in the SDD. A precise understanding of the spectrometer's response to electrons is crucial for accurately reconstructing the theoretical shape of the beta spectrum. To compute this response, GEANT4 simulations optimized for low-energy electron interactions are used and validated with a custom-made electron gun. In this article we present the performance of these simulations in reconstructing the electron spectra measured with SDDs of a 109Cd monochromatic source, both in vacuum and in air. The allowed beta spectrum of a 14C source was also measured and analyzed, proving that this system is suitable for the application in ASPECT-BET.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10300 - Physical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
1424-8220
Svazek periodika
24
Číslo periodika v rámci svazku
24
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
17
Strana od-do
8202
Kód UT WoS článku
001386984400001
EID výsledku v databázi Scopus
2-s2.0-85213250127