A Comparative Study of Regression Methods for Solving the Timepix Calibration Task
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F25%3A10510633" target="_blank" >RIV/00216208:11320/25:10510633 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/25:00387638 RIV/68407700:21460/25:00387638 RIV/68407700:21670/25:00387638 RIV/00216208:11110/25:10510633
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=.-d3MASk_7" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=.-d3MASk_7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s25216714" target="_blank" >10.3390/s25216714</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Comparative Study of Regression Methods for Solving the Timepix Calibration Task
Popis výsledku v původním jazyce
In this article, we provide a study of the energy calibration model used for Timepix-type detectors. The Timepix detectors, operating in Time-over-Threshold mode, measure information that needs to be mapped into the corresponding energies using a non-linear function. We consider three iterative algorithms, Gradient-Descent, Gauss-Newton and Levenberg-Marquardt algorithm, which we modify according to the calibration model constraints to perform better in terms of the convergence properties. Moreover, based on the variable projection method, we suggest a partial linearization of the calibration problem and provide results for this novel method.
Název v anglickém jazyce
A Comparative Study of Regression Methods for Solving the Timepix Calibration Task
Popis výsledku anglicky
In this article, we provide a study of the energy calibration model used for Timepix-type detectors. The Timepix detectors, operating in Time-over-Threshold mode, measure information that needs to be mapped into the corresponding energies using a non-linear function. We consider three iterative algorithms, Gradient-Descent, Gauss-Newton and Levenberg-Marquardt algorithm, which we modify according to the calibration model constraints to perform better in terms of the convergence properties. Moreover, based on the variable projection method, we suggest a partial linearization of the calibration problem and provide results for this novel method.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
<a href="/cs/project/GN22-12075O" target="_blank" >GN22-12075O: Laboratorní studium dopadů ledových zrn na družice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
1424-8220
Svazek periodika
25
Číslo periodika v rámci svazku
21
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
21
Strana od-do
6714
Kód UT WoS článku
001612974500001
EID výsledku v databázi Scopus
2-s2.0-105021624932