The Influence of Hypo Kinesis and Frequency Strain of a Car Ride on Mechanical Functions of Axial System Changes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F14%3A10281918" target="_blank" >RIV/00216208:11510/14:10281918 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Influence of Hypo Kinesis and Frequency Strain of a Car Ride on Mechanical Functions of Axial System Changes
Popis výsledku v původním jazyce
In our measurements, we used TVS method to detect mechanical changes of axial system. These mechanical changes can be base for discomfort feeling during monotonous driving in the car. The TVS method is based on the use of consequent application of continuously changing harmonic stimuli, which periodically differ between 5Hz and 160Hz, to the vertebrae C7 and L5. This wave is carried through the axial system and its acceleration on the spinous processes between C7 and S1 is scanned with the help of accelerometric sensors. According to the measured data, it is possible to identify changes of the mechanical properties of the human spine before and after applying hypo kinesis and frequency loading by the car ride. The research results proved the fact, thatthe TVS method is suitable for detection of the mechanical changes of axial system. It was also proved that changes caused by a monotonic and frequency loading influence he way of waves transfer through the axial system of the observed p
Název v anglickém jazyce
The Influence of Hypo Kinesis and Frequency Strain of a Car Ride on Mechanical Functions of Axial System Changes
Popis výsledku anglicky
In our measurements, we used TVS method to detect mechanical changes of axial system. These mechanical changes can be base for discomfort feeling during monotonous driving in the car. The TVS method is based on the use of consequent application of continuously changing harmonic stimuli, which periodically differ between 5Hz and 160Hz, to the vertebrae C7 and L5. This wave is carried through the axial system and its acceleration on the spinous processes between C7 and S1 is scanned with the help of accelerometric sensors. According to the measured data, it is possible to identify changes of the mechanical properties of the human spine before and after applying hypo kinesis and frequency loading by the car ride. The research results proved the fact, thatthe TVS method is suitable for detection of the mechanical changes of axial system. It was also proved that changes caused by a monotonic and frequency loading influence he way of waves transfer through the axial system of the observed p
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AQ - Bezpečnost a ochrana zdraví, člověk – stroj
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Carolinae. Kinanthropologica
ISSN
1212-1428
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
28-36
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—