A Comparison of Methods for Evaluating Body Composition in Elite Female Soccer Players
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F16%3A10336967" target="_blank" >RIV/00216208:11510/16:10336967 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Comparison of Methods for Evaluating Body Composition in Elite Female Soccer Players
Popis výsledku v původním jazyce
The aim of the research was to determine an accuracy of measurement based on intra-trial concurrent and convergent validity of body composition (BC). Measurements were obtained via bioelectrical impedance analysis (BIA) in comparison with the hydrodensitometry (HD) method in elite female soccer players (n = 14). BC was measured using three methods: bioelectrical impedance methods BIA 2000M and In Body 3.0, and HD. The fat mass (FM) measured by HD was 16.96+-3.86 percent, whereas it was 21.26+-5.77 percent when measured with BIA 2000M, and was even higher when measured by the In Body 3.0 device at 23.33+-3.52 percent. Effect size between BIA and HD was >0.87, convergent validity was lower than r<0.65, coefficient of determination was lower than R2<0.65, and a standard error of estimation was higher than >2.8. The results of the research showed that, without proper prediction equations for the specific population, the selected bioelectrical impedance analysers cannot be considered valid enough to assess the fat mass of elite female soccer players.
Název v anglickém jazyce
A Comparison of Methods for Evaluating Body Composition in Elite Female Soccer Players
Popis výsledku anglicky
The aim of the research was to determine an accuracy of measurement based on intra-trial concurrent and convergent validity of body composition (BC). Measurements were obtained via bioelectrical impedance analysis (BIA) in comparison with the hydrodensitometry (HD) method in elite female soccer players (n = 14). BC was measured using three methods: bioelectrical impedance methods BIA 2000M and In Body 3.0, and HD. The fat mass (FM) measured by HD was 16.96+-3.86 percent, whereas it was 21.26+-5.77 percent when measured with BIA 2000M, and was even higher when measured by the In Body 3.0 device at 23.33+-3.52 percent. Effect size between BIA and HD was >0.87, convergent validity was lower than r<0.65, coefficient of determination was lower than R2<0.65, and a standard error of estimation was higher than >2.8. The results of the research showed that, without proper prediction equations for the specific population, the selected bioelectrical impedance analysers cannot be considered valid enough to assess the fat mass of elite female soccer players.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AK - Sport a aktivity volného času
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-21791S" target="_blank" >GA16-21791S: Identifikace, diferenciace a diskriminace maladaptačných procesů u dětí a mládeže</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Anthropologist
ISSN
0972-0073
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
IN - Indická republika
Počet stran výsledku
10
Strana od-do
642-651
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84983480754