Force Effect of Strike and the Possibility of Causing a Skull Fracture of a Human Head a Skull Fracture of a Human Head
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F16%3A10364890" target="_blank" >RIV/00216208:11510/16:10364890 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Force Effect of Strike and the Possibility of Causing a Skull Fracture of a Human Head a Skull Fracture of a Human Head
Popis výsledku v původním jazyce
First, the article describes the force strike measurement of an athlete who performs competitively combat sports. Second, there are the results of scientific studies that deal with the human head injuries due to impacts of various kinds. These results were determined on the carcasses. During the actual measurement were determined time courses of forces impinging on the dynamometer plate, including size and the direction of the force. Dynamometer spanned forces up to 10000 N, frequency was set up at 1000 Hz, the accuracy of the estimate was 0.5 % of measured value. A composite plate was attached to a dynamometer which has a special steel construction. If we compare the results of force effect, we can find out that combat sports can cause fractures of the facial bones or other injuries of a human head or cervical vertebrae.
Název v anglickém jazyce
Force Effect of Strike and the Possibility of Causing a Skull Fracture of a Human Head a Skull Fracture of a Human Head
Popis výsledku anglicky
First, the article describes the force strike measurement of an athlete who performs competitively combat sports. Second, there are the results of scientific studies that deal with the human head injuries due to impacts of various kinds. These results were determined on the carcasses. During the actual measurement were determined time courses of forces impinging on the dynamometer plate, including size and the direction of the force. Dynamometer spanned forces up to 10000 N, frequency was set up at 1000 Hz, the accuracy of the estimate was 0.5 % of measured value. A composite plate was attached to a dynamometer which has a special steel construction. If we compare the results of force effect, we can find out that combat sports can cause fractures of the facial bones or other injuries of a human head or cervical vertebrae.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
DYNAMICAL SYSTEMS : MODELLING
ISBN
978-3-319-42401-9
ISSN
2194-1009
e-ISSN
neuvedeno
Počet stran výsledku
8
Strana od-do
353-360
Název nakladatele
Springer
Místo vydání
Switzerland
Místo konání akce
Łódź
Datum konání akce
7. 12. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000391880500028