Does a linear position transducer placed on a stick and belt provide sufficient validity and reliability of countermovement jump performance outcomes?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F22%3A10434641" target="_blank" >RIV/00216208:11510/22:10434641 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=6RxraO-9ip" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=6RxraO-9ip</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5114/biolsport.2022.104918" target="_blank" >10.5114/biolsport.2022.104918</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Does a linear position transducer placed on a stick and belt provide sufficient validity and reliability of countermovement jump performance outcomes?
Popis výsledku v původním jazyce
Manufacturers recommend that linear position transducers (LPTs) should be placed on the side of a barbell (or wooden dowel) to measure countermovement jump (CMJ) height, but the validity and reliability of this placement have not been compared to other attachment sites. Since this recommended attachment site is far from the centre of mass, a belt attachment where the LPT is placed between the feet may increase the validity and reliability of CMJ data. Thirty-six physical education students participated in the study (24.6 +- 4.3 years; 177.0 +- 7.7 cm; 77.2 +- 9.0 kg). Parameters from the two LPT attachments (barbell and belt) were simultaneously validated to force plate data, where the nature of bias was analysed (systematic vs random). The within-session and between-session reliability of both attachment sites were compared to force plate data using a test-retest protocol of two sets of 5 CMJs separated by 7 days. The LPT provided highly reliable and valid measures of peak force, mean force, mean power, and jump height, where the bias was mostly systematic (r2 > 0.7; ICC > 0.9). Peak velocity, mean velocity, and peak power were in very good agreement with the force plate and were highly reliable (r2 > 0.5; ICC > 0.7). Therefore, both attachment sites produced similar results with a systematic bias compared to force plate data. Thus, both attachment sites seem to be valid for assessing CMJs when the measuring tool and site remain consistent across measurements. However, if LPT data are to be compared to force plate data, recalculation equations should be used.
Název v anglickém jazyce
Does a linear position transducer placed on a stick and belt provide sufficient validity and reliability of countermovement jump performance outcomes?
Popis výsledku anglicky
Manufacturers recommend that linear position transducers (LPTs) should be placed on the side of a barbell (or wooden dowel) to measure countermovement jump (CMJ) height, but the validity and reliability of this placement have not been compared to other attachment sites. Since this recommended attachment site is far from the centre of mass, a belt attachment where the LPT is placed between the feet may increase the validity and reliability of CMJ data. Thirty-six physical education students participated in the study (24.6 +- 4.3 years; 177.0 +- 7.7 cm; 77.2 +- 9.0 kg). Parameters from the two LPT attachments (barbell and belt) were simultaneously validated to force plate data, where the nature of bias was analysed (systematic vs random). The within-session and between-session reliability of both attachment sites were compared to force plate data using a test-retest protocol of two sets of 5 CMJs separated by 7 days. The LPT provided highly reliable and valid measures of peak force, mean force, mean power, and jump height, where the bias was mostly systematic (r2 > 0.7; ICC > 0.9). Peak velocity, mean velocity, and peak power were in very good agreement with the force plate and were highly reliable (r2 > 0.5; ICC > 0.7). Therefore, both attachment sites produced similar results with a systematic bias compared to force plate data. Thus, both attachment sites seem to be valid for assessing CMJs when the measuring tool and site remain consistent across measurements. However, if LPT data are to be compared to force plate data, recalculation equations should be used.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BIOLOGY OF SPORT [online]
ISSN
2083-1862
e-ISSN
2083-1862
Svazek periodika
39
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
341-348
Kód UT WoS článku
000759195200012
EID výsledku v databázi Scopus
2-s2.0-85119931529