Walking on a Balance Beam as a New Measure of Dynamic Balance to Predict Falls in Older Adults and Patients with Neurological Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F24%3A10481120" target="_blank" >RIV/00216208:11510/24:10481120 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5xE358fYU6" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5xE358fYU6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s40798-024-00723-7" target="_blank" >10.1186/s40798-024-00723-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Walking on a Balance Beam as a New Measure of Dynamic Balance to Predict Falls in Older Adults and Patients with Neurological Conditions
Popis výsledku v původním jazyce
Background Beam walking is a new test to estimate dynamic balance. We characterized dynamic balance measured by the distance walked on beams of different widths in five age groups of healthy adults (20, 30, 40, 50, 60 years) and individuals with neurological conditions (i.e., Parkinson, multiple sclerosis, stroke, age: 66.9 years) and determined if beam walking distance predicted prospective falls over 12 months. Methods Individuals with (n = 97) and without neurological conditions (n = 99, healthy adults, age 20-60) participated in this prospective longitudinal study. Falls analyses over 12 months were conducted. The summed distance walked under single (walking only) and dual-task conditions (walking and serial subtraction by 7 between 300 to 900) on three beams (4, 8, and 12-cm wide) was used in the analyses. Additional functional tests comprised grip strength and the Short Physical Performance Battery. Results Beam walking distance was unaffected on the 12-cm-wide beam in the healthy adult groups. The distance walked on the 8-cm-wide beam decreased by 0.34 m in the 20-year-old group. This reduction was similar to 3 x greater, 1.1 m, in the 60-year-old group. In patients, beam walking distances decreased sharply by 0.8 m on the 8 versus 12 cm beam and by additional 1.6 m on the 4 versus 8 cm beam. Beam walking distance under single and dual-task conditions was linearly but weakly associated with age (R-2 = 0.21 for single task, R-2 = 0.27 for dual-task). Age, disease, and beam width affected distance walked on the beam. Beam walking distance predicted future falls in the combined population of healthy adults and patients with neurological conditions. Based on receiver operating characteristic curve analyses using data from the entire study population, walking similar to 8.0 of the 12 m maximum on low-lying beams predicted future fallers with reasonable accuracy. Conclusion Balance beam walking is a new but worthwhile measure of dynamic balance to predict falls in the combined population of healthy adults and patients with neurological conditions. Future studies are needed to evaluate the predictive capability of beam walking separately in more homogenous populations.
Název v anglickém jazyce
Walking on a Balance Beam as a New Measure of Dynamic Balance to Predict Falls in Older Adults and Patients with Neurological Conditions
Popis výsledku anglicky
Background Beam walking is a new test to estimate dynamic balance. We characterized dynamic balance measured by the distance walked on beams of different widths in five age groups of healthy adults (20, 30, 40, 50, 60 years) and individuals with neurological conditions (i.e., Parkinson, multiple sclerosis, stroke, age: 66.9 years) and determined if beam walking distance predicted prospective falls over 12 months. Methods Individuals with (n = 97) and without neurological conditions (n = 99, healthy adults, age 20-60) participated in this prospective longitudinal study. Falls analyses over 12 months were conducted. The summed distance walked under single (walking only) and dual-task conditions (walking and serial subtraction by 7 between 300 to 900) on three beams (4, 8, and 12-cm wide) was used in the analyses. Additional functional tests comprised grip strength and the Short Physical Performance Battery. Results Beam walking distance was unaffected on the 12-cm-wide beam in the healthy adult groups. The distance walked on the 8-cm-wide beam decreased by 0.34 m in the 20-year-old group. This reduction was similar to 3 x greater, 1.1 m, in the 60-year-old group. In patients, beam walking distances decreased sharply by 0.8 m on the 8 versus 12 cm beam and by additional 1.6 m on the 4 versus 8 cm beam. Beam walking distance under single and dual-task conditions was linearly but weakly associated with age (R-2 = 0.21 for single task, R-2 = 0.27 for dual-task). Age, disease, and beam width affected distance walked on the beam. Beam walking distance predicted future falls in the combined population of healthy adults and patients with neurological conditions. Based on receiver operating characteristic curve analyses using data from the entire study population, walking similar to 8.0 of the 12 m maximum on low-lying beams predicted future fallers with reasonable accuracy. Conclusion Balance beam walking is a new but worthwhile measure of dynamic balance to predict falls in the combined population of healthy adults and patients with neurological conditions. Future studies are needed to evaluate the predictive capability of beam walking separately in more homogenous populations.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sports Medicine - Open
ISSN
2199-1170
e-ISSN
2198-9761
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
59
Kód UT WoS článku
001229415500001
EID výsledku v databázi Scopus
2-s2.0-85194105189