Detekce ischemie myokardu pomocí Markovových modelů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F03%3A00008391" target="_blank" >RIV/00216224:14110/03:00008391 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Myocardial Ischemia Using Hidden Markov Models
Popis výsledku v původním jazyce
The paper deals with detection of myocardial ischemia by analysis of electrophysiological changes within QRS complexes of electrocardiograms (ECG). ECG signals were analysed by continuous wavelet transform (CWT). Time - frequency spectra of QRS complexeswere used as an input of a detection system based on hidden Markov models (HMMs). Parameters of the used HMMs were assessed to recommend their optimal values. The presented results show that HMM analysis of ECGs preprocessed by CWT can be used for earlydetection of myocardial ischemia. Eleven Langendorff perfused rabbit hearts were used to record training and test data to learn Markov models. An average value of resulting sensitivity and specificity of detection system was around 0.9 depending on parameter setting of the models.
Název v anglickém jazyce
Detection of Myocardial Ischemia Using Hidden Markov Models
Popis výsledku anglicky
The paper deals with detection of myocardial ischemia by analysis of electrophysiological changes within QRS complexes of electrocardiograms (ECG). ECG signals were analysed by continuous wavelet transform (CWT). Time - frequency spectra of QRS complexeswere used as an input of a detection system based on hidden Markov models (HMMs). Parameters of the used HMMs were assessed to recommend their optimal values. The presented results show that HMM analysis of ECGs preprocessed by CWT can be used for earlydetection of myocardial ischemia. Eleven Langendorff perfused rabbit hearts were used to record training and test data to learn Markov models. An average value of resulting sensitivity and specificity of detection system was around 0.9 depending on parameter setting of the models.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F01%2F1494" target="_blank" >GA102/01/1494: Optické snímání akčních potenciálů a jeho využití v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 25th Annual International Conference IEEE EMBS
ISBN
0-7803-7789-3
ISSN
1094-687X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE EMBS
Místo vydání
Cancún, Mexico
Místo konání akce
Cancún
Datum konání akce
1. 1. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000189395300745