Srovnání akustické denzitometrie a dobutaminové echokardiografie v diagnostice viability myokardu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F04%3A00010035" target="_blank" >RIV/00216224:14110/04:00010035 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of myocardial viability by acoustic densitometry. Comparison with dobutamine echocardiography
Popis výsledku v původním jazyce
Aim: The purpose of this study has been to compare acoustic densitometry and dobutamine echocardiography for an assessment of myocardial viability. Methods: Fifty-four patients with coronary artery disease and dysfunctional myocardial segments, who werereferred for myocardial revascularization, underwent a viability assessment using acoustic densitometry. Thirty-four patients underwent also low-dose dobutamine echocardiography. Amplitude of cyclic variation of integrated backscatter (CVIB) was evaluated from each dysfunctional segment. The receiver operating characteristics curve analysis was applied to determine the optimal cut off value of CVIB for distinction between viable and nonviable dysfunctional myocardium. Results of the two techniques werecompared to follow-up resting echocardiography, which was performed at a mean of 3 months after successful revascularization in order to assess the recovery of function in revascularized, initially dysfunctional segments. Echocardiography
Název v anglickém jazyce
Assessment of myocardial viability by acoustic densitometry. Comparison with dobutamine echocardiography
Popis výsledku anglicky
Aim: The purpose of this study has been to compare acoustic densitometry and dobutamine echocardiography for an assessment of myocardial viability. Methods: Fifty-four patients with coronary artery disease and dysfunctional myocardial segments, who werereferred for myocardial revascularization, underwent a viability assessment using acoustic densitometry. Thirty-four patients underwent also low-dose dobutamine echocardiography. Amplitude of cyclic variation of integrated backscatter (CVIB) was evaluated from each dysfunctional segment. The receiver operating characteristics curve analysis was applied to determine the optimal cut off value of CVIB for distinction between viable and nonviable dysfunctional myocardium. Results of the two techniques werecompared to follow-up resting echocardiography, which was performed at a mean of 3 months after successful revascularization in order to assess the recovery of function in revascularized, initially dysfunctional segments. Echocardiography
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bratislavské Lekárské Listy
ISSN
0006-9248
e-ISSN
—
Svazek periodika
105
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
1
Strana od-do
174
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—