Hodnocení efektivity baroreflexu v potlačení variability systolického krevního tlaku
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F08%3A00027234" target="_blank" >RIV/00216224:14110/08:00027234 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of effectivity of baroreflex to suppress the systolic blood pressure variability
Popis výsledku v původním jazyce
The evaluation of the ability to suppress systolic blood pressure variability (SBPv) by baroreflex at a frequency of 0.1 Hz was the aim of the present study. Fifty eight subjects (20 to 22 years of age) were examined in the rest, systolic and diastolic blood pressures (SBP, DBP) and inter beat intervals (IBI) were recorded beat to beat for 5 min (Finapres, controlled breathing at a frequency of 0.33 Hz). Baroreflex sensitivity expressed in ms/mmHg (BRS) and in mHz/mmHg (BRSf) was determined by spectralmethods. The quantitative effects of BRS and BRSf on SBPv were evaluated after both variables were expressed as multiples of standard deviations. Our analysis revealed that the cardiac interval independent index BRSf is a better indicator for evaluationof the effectivity of baroreflex sensitivity to suppress the SBPv than the cardiac interval dependent index BRS.
Název v anglickém jazyce
Evaluation of effectivity of baroreflex to suppress the systolic blood pressure variability
Popis výsledku anglicky
The evaluation of the ability to suppress systolic blood pressure variability (SBPv) by baroreflex at a frequency of 0.1 Hz was the aim of the present study. Fifty eight subjects (20 to 22 years of age) were examined in the rest, systolic and diastolic blood pressures (SBP, DBP) and inter beat intervals (IBI) were recorded beat to beat for 5 min (Finapres, controlled breathing at a frequency of 0.33 Hz). Baroreflex sensitivity expressed in ms/mmHg (BRS) and in mHz/mmHg (BRSf) was determined by spectralmethods. The quantitative effects of BRS and BRSf on SBPv were evaluated after both variables were expressed as multiples of standard deviations. Our analysis revealed that the cardiac interval independent index BRSf is a better indicator for evaluationof the effectivity of baroreflex sensitivity to suppress the SBPv than the cardiac interval dependent index BRS.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analysis of Biomedical Signals and Images
ISSN
1211-412X
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—