Background Bone marrow (BM) examination is routinely performed for minimal residual disease monitoring in leukemia patients. By contrast, chimerism is usually tested from peripheral blood (PB), and, surprisingly, little is known about the clinical impactof the chimerism status in BM. Patients and Methods 226 pairs of PB and BM samples obtained from 102 adult patients were investigated. Frequencies of diagnoses within samples were as follows: AML 42%, CML 24%, ALL 11%, CLL 7%, MDS 7%, other hematological malignancies 9%. Assessment of chimerism was performed using either capillary electrophoresis with fluorescence detection, or quantitative real-time PCR with one order of magnitude higher sensitivity of mixed chimerism detection. Results Mixed chimerism in BM was detected even more than 9 years after transplantation, however, on the other hand, complete donor chimerism was also observed as early as day +35.
Název v anglickém jazyce
Bone marrow versus peripheral blood: comparison of the chimerism analysis
Popis výsledku anglicky
Background Bone marrow (BM) examination is routinely performed for minimal residual disease monitoring in leukemia patients. By contrast, chimerism is usually tested from peripheral blood (PB), and, surprisingly, little is known about the clinical impactof the chimerism status in BM. Patients and Methods 226 pairs of PB and BM samples obtained from 102 adult patients were investigated. Frequencies of diagnoses within samples were as follows: AML 42%, CML 24%, ALL 11%, CLL 7%, MDS 7%, other hematological malignancies 9%. Assessment of chimerism was performed using either capillary electrophoresis with fluorescence detection, or quantitative real-time PCR with one order of magnitude higher sensitivity of mixed chimerism detection. Results Mixed chimerism in BM was detected even more than 9 years after transplantation, however, on the other hand, complete donor chimerism was also observed as early as day +35.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů