Evaluation and comparison of composite and split-thickness skin grafts using Cutometer MPA 580
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F10%3A00052256" target="_blank" >RIV/00216224:14110/10:00052256 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation and comparison of composite and split-thickness skin grafts using Cutometer MPA 580
Popis výsledku v původním jazyce
Background. In our preliminary experiments we found that composite skin grafts consisting of allogeneic acellular dermis and thin epidermal autologous grafts applied to the excised burn wound in one stage led to better results in terms of vis-coelastic properties than autologous split-thickness skin grafts. Patients and methods. In ten burn patients we applied composite skin grafts consisting of allogeneic acellular dermis and thin epidermal autologous grafts and followed the quality of the reconstructed skin cover with a special device, Cutometer MPA 580, over a period of four years. Results. The cutometric curves demonstrated better viscoelastic properties in composite skin grafts than in conventional split-thickness skin grafts after four years. Wefound Cutometer MPA 580 to be an advantageous device for the objectification of improved quality of reconstructed skin cover. Discussion.
Název v anglickém jazyce
Evaluation and comparison of composite and split-thickness skin grafts using Cutometer MPA 580
Popis výsledku anglicky
Background. In our preliminary experiments we found that composite skin grafts consisting of allogeneic acellular dermis and thin epidermal autologous grafts applied to the excised burn wound in one stage led to better results in terms of vis-coelastic properties than autologous split-thickness skin grafts. Patients and methods. In ten burn patients we applied composite skin grafts consisting of allogeneic acellular dermis and thin epidermal autologous grafts and followed the quality of the reconstructed skin cover with a special device, Cutometer MPA 580, over a period of four years. Results. The cutometric curves demonstrated better viscoelastic properties in composite skin grafts than in conventional split-thickness skin grafts after four years. Wefound Cutometer MPA 580 to be an advantageous device for the objectification of improved quality of reconstructed skin cover. Discussion.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Burns and Fire Disasters
ISSN
1121-1539
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
208-213
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—