Purpose: The standard diagnostics of celiac disease (CD) is based on the positivity of specific antibodies and enterobiopsy. But there are several different forms and stages of the disease and the diagnostics could be complicated. The aim of our study was to demonstrate whether the ultrasound is able to reveal CD and the possibility of the ultrasound examination as a screening method. Materials and methods: During 2 years 100 patients with consequently verified CD were examined. We used the ultrasound machine Phillips iU22 with 9 and 12MHz linear probe. We observed several ultrasound signs of celiac disease. All these expressed parameters or at least one of them we considered as the positive ultrasound examination. The results were statistically elaborated using the ROC analysis. Results: Based on these statistical results was revealed, that the sensitivity of the ultrasound examination among patients, where all ultrasound signs denoting CD were expressed, was 81%. The specificity was
Název v anglickém jazyce
Dependence of the clinical symptoms on the ultrasound findings by patients with celiac disease ? prospective study
Popis výsledku anglicky
Purpose: The standard diagnostics of celiac disease (CD) is based on the positivity of specific antibodies and enterobiopsy. But there are several different forms and stages of the disease and the diagnostics could be complicated. The aim of our study was to demonstrate whether the ultrasound is able to reveal CD and the possibility of the ultrasound examination as a screening method. Materials and methods: During 2 years 100 patients with consequently verified CD were examined. We used the ultrasound machine Phillips iU22 with 9 and 12MHz linear probe. We observed several ultrasound signs of celiac disease. All these expressed parameters or at least one of them we considered as the positive ultrasound examination. The results were statistically elaborated using the ROC analysis. Results: Based on these statistical results was revealed, that the sensitivity of the ultrasound examination among patients, where all ultrasound signs denoting CD were expressed, was 81%. The specificity was
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů