EXAMINATION OF THE VISUAL ACUITY ON THE LCD OPTOTYPE WITH WHOLE-LINE AND INTERPOLATION METHOD
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F12%3A00060085" target="_blank" >RIV/00216224:14110/12:00060085 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EXAMINATION OF THE VISUAL ACUITY ON THE LCD OPTOTYPE WITH WHOLE-LINE AND INTERPOLATION METHOD
Popis výsledku v původním jazyce
The goal of this work is to show the possibility of us using the LCD optotype in common optometrist practice. Furthermore two commonly used methods for measuring visual acuity will be compared. 69 respondents were used for the measurements. The respondents were divided into two groups according to the measured LCD optotype. The visual acuity was measured using the whole-line method on modified Snellen charts as well as the interpolation method on ETDRS charts. Measurements were taken on the Sloan letters and on the Landolt rings. The charts for the before mentioned methods were selected according to everyday optometrist practice. The results show the test-retest variability (reliability) of given methods. By comparing the results the precision of a given method can by estimated. The results show that the two methods do not give the same resulting values of visual acuity. Measuring the visual acuity has great importance since it serves as a basis for following examinations for eye patho
Název v anglickém jazyce
EXAMINATION OF THE VISUAL ACUITY ON THE LCD OPTOTYPE WITH WHOLE-LINE AND INTERPOLATION METHOD
Popis výsledku anglicky
The goal of this work is to show the possibility of us using the LCD optotype in common optometrist practice. Furthermore two commonly used methods for measuring visual acuity will be compared. 69 respondents were used for the measurements. The respondents were divided into two groups according to the measured LCD optotype. The visual acuity was measured using the whole-line method on modified Snellen charts as well as the interpolation method on ETDRS charts. Measurements were taken on the Sloan letters and on the Landolt rings. The charts for the before mentioned methods were selected according to everyday optometrist practice. The results show the test-retest variability (reliability) of given methods. By comparing the results the precision of a given method can by estimated. The results show that the two methods do not give the same resulting values of visual acuity. Measuring the visual acuity has great importance since it serves as a basis for following examinations for eye patho
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů