Long-term patency of a RaK collagen vascular prosthesis - single centre results during a 10 year follow-up
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00070189" target="_blank" >RIV/00216224:14110/13:00070189 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/13:00060590
Výsledek na webu
<a href="http://dx.doi.org/10.4149/BLL_2013_004" target="_blank" >http://dx.doi.org/10.4149/BLL_2013_004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4149/BLL_2013_004" target="_blank" >10.4149/BLL_2013_004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-term patency of a RaK collagen vascular prosthesis - single centre results during a 10 year follow-up
Popis výsledku v původním jazyce
The aim of this retrospective study was to evaluate the results of vascular,operations based on the RaK prostheses, with a particular attention paid to their long-term patency. The study included 105 patients who were operated on in the period from 1992to 1996. Vascular surgery was performed in the aortofemoral area and the underlying diagnoses were Leriche syndrome, asymptomatic abdominal aortic aneurysm, iliac artery stenosis or occlusion and symptomatic abdominal aortic aneurysm. During the mean follow-up time of 96 months (range 28-144), 8 patients (7.6 %) were lost to follow-up and 23 patients (21.9 %) died. At 12, 36, 60 and 120 months after surgery, the prostheses were patent in 99 %, 98 %, 93 % and 89 % of the patients, respectively. It is concluded that the RaK collagen prosthesis is the device of high quality and parameters comparable with the other types of knitted vascular prostheses currently used (Tab. 3, Fig. 4, Ref. 17).
Název v anglickém jazyce
Long-term patency of a RaK collagen vascular prosthesis - single centre results during a 10 year follow-up
Popis výsledku anglicky
The aim of this retrospective study was to evaluate the results of vascular,operations based on the RaK prostheses, with a particular attention paid to their long-term patency. The study included 105 patients who were operated on in the period from 1992to 1996. Vascular surgery was performed in the aortofemoral area and the underlying diagnoses were Leriche syndrome, asymptomatic abdominal aortic aneurysm, iliac artery stenosis or occlusion and symptomatic abdominal aortic aneurysm. During the mean follow-up time of 96 months (range 28-144), 8 patients (7.6 %) were lost to follow-up and 23 patients (21.9 %) died. At 12, 36, 60 and 120 months after surgery, the prostheses were patent in 99 %, 98 %, 93 % and 89 % of the patients, respectively. It is concluded that the RaK collagen prosthesis is the device of high quality and parameters comparable with the other types of knitted vascular prostheses currently used (Tab. 3, Fig. 4, Ref. 17).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bratislava Medical Journal - Bratislavské lekárske listy
ISSN
0006-9248
e-ISSN
—
Svazek periodika
114
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
4
Strana od-do
15-18
Kód UT WoS článku
000313776200004
EID výsledku v databázi Scopus
—