Searching for an appropriate image-guided radiotherapy method in prostate cancer ? implications for safety margin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F14%3A00078689" target="_blank" >RIV/00216224:14110/14:00078689 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/14:43875323
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Searching for an appropriate image-guided radiotherapy method in prostate cancer ? implications for safety margin
Popis výsledku v původním jazyce
Aims and background. The aim of the study was to compare the safety margin width using skin marks, pelvic skeleton-based targeting and adaptive protocol combining cone-beam computed tomography and kilovoltage image matching. Methods. A total of 434 consecutive patients were treated by image-guided radiotherapy from November 2008 to April 2012. An adaptive protocol combining cone-beam computed tomography and kilovoltage image matching with individualized safety margin calculation according to the Van Herk method was used in a total of 201 patients. The remaining 233 patients had their setup corrected using cone-beam computed tomography daily. Results. Analysis of the 3,137 cone-beam computed tomography images (201 patients) revealed that the margins between the clinical target volume and planning target volume with skin marks registration should be 1.24 cm in the anteroposterior, 0.98 cm in the craniocaudal, and 1.03 cm in the laterolateral direction.
Název v anglickém jazyce
Searching for an appropriate image-guided radiotherapy method in prostate cancer ? implications for safety margin
Popis výsledku anglicky
Aims and background. The aim of the study was to compare the safety margin width using skin marks, pelvic skeleton-based targeting and adaptive protocol combining cone-beam computed tomography and kilovoltage image matching. Methods. A total of 434 consecutive patients were treated by image-guided radiotherapy from November 2008 to April 2012. An adaptive protocol combining cone-beam computed tomography and kilovoltage image matching with individualized safety margin calculation according to the Van Herk method was used in a total of 201 patients. The remaining 233 patients had their setup corrected using cone-beam computed tomography daily. Results. Analysis of the 3,137 cone-beam computed tomography images (201 patients) revealed that the margins between the clinical target volume and planning target volume with skin marks registration should be 1.24 cm in the anteroposterior, 0.98 cm in the craniocaudal, and 1.03 cm in the laterolateral direction.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Tumori
ISSN
0300-8916
e-ISSN
—
Svazek periodika
100
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
6
Strana od-do
518-523
Kód UT WoS článku
000348335400008
EID výsledku v databázi Scopus
—