Radiofrequency tissue ablation inside of metal stent - A thermographis study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F14%3A00080134" target="_blank" >RIV/00216224:14110/14:00080134 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.irbm.2014.02.007" target="_blank" >http://dx.doi.org/10.1016/j.irbm.2014.02.007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.irbm.2014.02.007" target="_blank" >10.1016/j.irbm.2014.02.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radiofrequency tissue ablation inside of metal stent - A thermographis study
Popis výsledku v původním jazyce
Biliary stents are used to treat obstructions that occur in the bile ducts. The stents can be blocked by new tissue in a few months after their implanting. This complication can be solved by using radiofrequency ablation. The present article deals with monitoring of the process of monopolar thermoablation of a metal stent by using an infrared camera ex vivo. The metallic EGIS Biliary stents 10 mm × 80 mm were used in experiments; radiofrequency ablation due by catheter EndoHPB 8F at 460 kHz was used. The Flir B200 thermocamera was used for monitoring. The results show an increase in temperature of the stent's material during thermoablation process. It is believed that the metal stent becomes an active electrode. The results show an increase in temperature of the stent and the surrounding tissue during the treatment. Temperature distribution measured on stent was affected by power applied and obviously non-homogeneous. The maximum temperature values were observed at the ends of the sten
Název v anglickém jazyce
Radiofrequency tissue ablation inside of metal stent - A thermographis study
Popis výsledku anglicky
Biliary stents are used to treat obstructions that occur in the bile ducts. The stents can be blocked by new tissue in a few months after their implanting. This complication can be solved by using radiofrequency ablation. The present article deals with monitoring of the process of monopolar thermoablation of a metal stent by using an infrared camera ex vivo. The metallic EGIS Biliary stents 10 mm × 80 mm were used in experiments; radiofrequency ablation due by catheter EndoHPB 8F at 460 kHz was used. The Flir B200 thermocamera was used for monitoring. The results show an increase in temperature of the stent's material during thermoablation process. It is believed that the metal stent becomes an active electrode. The results show an increase in temperature of the stent and the surrounding tissue during the treatment. Temperature distribution measured on stent was affected by power applied and obviously non-homogeneous. The maximum temperature values were observed at the ends of the sten
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14586" target="_blank" >NT14586: Choledochoskopem navigovaná radiofrekvenční ablace žlučových cest.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IRBM
ISSN
1959-0318
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
164-169
Kód UT WoS článku
000339412400007
EID výsledku v databázi Scopus
—