Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00082233" target="_blank" >RIV/00216224:14110/15:00082233 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/15:10284700 RIV/00216208:11130/15:10284700 RIV/00159816:_____/15:00061303 RIV/00064203:_____/15:10284700
Výsledek na webu
<a href="http://dx.doi.org/10.1177/0284185114533683" target="_blank" >http://dx.doi.org/10.1177/0284185114533683</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0284185114533683" target="_blank" >10.1177/0284185114533683</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
Popis výsledku v původním jazyce
Background: Computed tomography (CT) colonography is a well established modality for the examination of symptomatic patients as well as in screening. Recent technical advances in improving image quality by iterative reconstruction contribute to the reduction of the radiation dose which is a major concern in CT imaging. Purpose: To evaluate image quality of ultralow-dose submilisievert CT colonography using hybrid iterative reconstruction technique. Material and Methods: Sixteen patients underwent contrast-enhanced CT colonography with standard protocol in supine position and ultralow-dose protocol in prone position. Ultralow-dose datasets were reconstructed with filtered back projection and an advanced hybrid iterative reconstruction technique. Two radiologists independently evaluated 96 colonic segments for image quality in the endoluminal view and axial thin sections.
Název v anglickém jazyce
Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
Popis výsledku anglicky
Background: Computed tomography (CT) colonography is a well established modality for the examination of symptomatic patients as well as in screening. Recent technical advances in improving image quality by iterative reconstruction contribute to the reduction of the radiation dose which is a major concern in CT imaging. Purpose: To evaluate image quality of ultralow-dose submilisievert CT colonography using hybrid iterative reconstruction technique. Material and Methods: Sixteen patients underwent contrast-enhanced CT colonography with standard protocol in supine position and ultralow-dose protocol in prone position. Ultralow-dose datasets were reconstructed with filtered back projection and an advanced hybrid iterative reconstruction technique. Two radiologists independently evaluated 96 colonic segments for image quality in the endoluminal view and axial thin sections.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Radiologica
ISSN
0284-1851
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
517-525
Kód UT WoS článku
000352778600002
EID výsledku v databázi Scopus
—