Prospective randomized comparison of the trans-obturator mid-uretrhr al sling and the single-incision sling in women with stress urinary incontinence: One-year follow-up study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00083298" target="_blank" >RIV/00216224:14110/15:00083298 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00192-015-2713-x" target="_blank" >http://dx.doi.org/10.1007/s00192-015-2713-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00192-015-2713-x" target="_blank" >10.1007/s00192-015-2713-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Prospective randomized comparison of the trans-obturator mid-uretrhr al sling and the single-incision sling in women with stress urinary incontinence: One-year follow-up study
Popis výsledku v původním jazyce
Mid-urethral slings (MUS) represent a gold standard in the treatment of female stress urinary incontinence (SUI). Second generation trans-obturator slings (TOT) have proven to be as effective as retropubic slings (TVT) with fewer major complications. A third generation MUS inserted through a single vaginal incision (SIS) has become a means to overcoming significant post-operative groin pain. Novel types of SIS with a more robust and adjustable anchoring mechanism can assure adequate long-lasting attachment to the obturator membrane.
Název v anglickém jazyce
Prospective randomized comparison of the trans-obturator mid-uretrhr al sling and the single-incision sling in women with stress urinary incontinence: One-year follow-up study
Popis výsledku anglicky
Mid-urethral slings (MUS) represent a gold standard in the treatment of female stress urinary incontinence (SUI). Second generation trans-obturator slings (TOT) have proven to be as effective as retropubic slings (TVT) with fewer major complications. A third generation MUS inserted through a single vaginal incision (SIS) has become a means to overcoming significant post-operative groin pain. Novel types of SIS with a more robust and adjustable anchoring mechanism can assure adequate long-lasting attachment to the obturator membrane.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FK - Gynekologie a porodnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů