Accuracy Analysis of Narrow Band Imaging (NBI) Bronchoscopy Compared To White Light Bronchoscopy in the Diagnostics of Lung Tumours
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00083334" target="_blank" >RIV/00216224:14110/15:00083334 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accuracy Analysis of Narrow Band Imaging (NBI) Bronchoscopy Compared To White Light Bronchoscopy in the Diagnostics of Lung Tumours
Popis výsledku v původním jazyce
Background: Bronchoscopy plays an important role in the diagnostics of lung tumours. One of the technologies looking for their way in the diagnostics of pulmonary diseases is narrow band imaging. The aim of this study was to compare accuracy of examinations in the NBI and the white light (WL) modes in relation to biopsy results for the diagnoses of malignant tumour or severe dysplasia. Methods and results: A group of 500 patients have undergone a bronchoscopic examination in the NBI mode and afterwardsin the white light. Biopsies were taken from all areas with pathological findings in both the modes for histological examination. Pathological bronchoscopic images were detected in a total of 382 patients. Positive findings in both the NBI mode and the WL mode were detected in 331 patients (66.2%). Discordant NBI-/WL+ findings were detected in 29 cases (5.8%) and discordant NBI+/WL- findings were detected in 22 cases (4.4%). The relative sensitivity of NBI compared to WL is 1.06 (p <
Název v anglickém jazyce
Accuracy Analysis of Narrow Band Imaging (NBI) Bronchoscopy Compared To White Light Bronchoscopy in the Diagnostics of Lung Tumours
Popis výsledku anglicky
Background: Bronchoscopy plays an important role in the diagnostics of lung tumours. One of the technologies looking for their way in the diagnostics of pulmonary diseases is narrow band imaging. The aim of this study was to compare accuracy of examinations in the NBI and the white light (WL) modes in relation to biopsy results for the diagnoses of malignant tumour or severe dysplasia. Methods and results: A group of 500 patients have undergone a bronchoscopic examination in the NBI mode and afterwardsin the white light. Biopsies were taken from all areas with pathological findings in both the modes for histological examination. Pathological bronchoscopic images were detected in a total of 382 patients. Positive findings in both the NBI mode and the WL mode were detected in 331 patients (66.2%). Discordant NBI-/WL+ findings were detected in 29 cases (5.8%) and discordant NBI+/WL- findings were detected in 22 cases (4.4%). The relative sensitivity of NBI compared to WL is 1.06 (p <
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FC - Pneumologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Health Sciences and Research
ISSN
2249-9571
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
IN - Indická republika
Počet stran výsledku
9
Strana od-do
80-88
Kód UT WoS článku
—