Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00086075" target="_blank" >RIV/00216224:14110/15:00086075 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2214/AJR.14.13957" target="_blank" >http://dx.doi.org/10.2214/AJR.14.13957</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2214/AJR.14.13957" target="_blank" >10.2214/AJR.14.13957</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate
Popis výsledku v původním jazyce
OBJECTIVE. The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. MATERIALS AND METHODS. A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identicaliodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocolC, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose.
Název v anglickém jazyce
Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate
Popis výsledku anglicky
OBJECTIVE. The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. MATERIALS AND METHODS. A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identicaliodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocolC, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
American Journal of Roentgenology
ISSN
0361-803X
e-ISSN
—
Svazek periodika
205
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
1332-1338
Kód UT WoS článku
000365320400039