Endoluminal radiofrequency ablation of malignant biliary stenoses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00087460" target="_blank" >RIV/00216224:14110/15:00087460 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s13244-015-0387-z" target="_blank" >http://dx.doi.org/10.1007/s13244-015-0387-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s13244-015-0387-z" target="_blank" >10.1007/s13244-015-0387-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Endoluminal radiofrequency ablation of malignant biliary stenoses
Popis výsledku v původním jazyce
Purpose: To prove efficacy of endoluminal radiofrequency ablation before stenting of malignant biliary stenoses. Methods and Materials: 54 patients with histologically proven malignant biliary stenoses have been enrolled in a prospective randomised study from 2010. 73 non-covered self-expandable metal stents were inserted. In group A (n=22) the endoluminal ablation with a bipolar radiofrequency catheter (EndoHPB;EMcision Ltd.,London,UK) was performed 0-48hours prior to the stent insertion, in group B (n=32) the stent was implanted without a prior ablation. The primary endpoints of the study were to determine the rate of complications, duration of stent patency and survival of patients (Kaplan-Meyer analysis). Results: No major complications related to the stent insertion and endoluminal ablation were recorded. 30 day mortality was 3.7%. The average primary stent patency was 5.6 and 5.2 months in group A and B, respectively, 3-months and 6-months stent failure was 9.1% and 13.
Název v anglickém jazyce
Endoluminal radiofrequency ablation of malignant biliary stenoses
Popis výsledku anglicky
Purpose: To prove efficacy of endoluminal radiofrequency ablation before stenting of malignant biliary stenoses. Methods and Materials: 54 patients with histologically proven malignant biliary stenoses have been enrolled in a prospective randomised study from 2010. 73 non-covered self-expandable metal stents were inserted. In group A (n=22) the endoluminal ablation with a bipolar radiofrequency catheter (EndoHPB;EMcision Ltd.,London,UK) was performed 0-48hours prior to the stent insertion, in group B (n=32) the stent was implanted without a prior ablation. The primary endpoints of the study were to determine the rate of complications, duration of stent patency and survival of patients (Kaplan-Meyer analysis). Results: No major complications related to the stent insertion and endoluminal ablation were recorded. 30 day mortality was 3.7%. The average primary stent patency was 5.6 and 5.2 months in group A and B, respectively, 3-months and 6-months stent failure was 9.1% and 13.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14586" target="_blank" >NT14586: Choledochoskopem navigovaná radiofrekvenční ablace žlučových cest.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů