Optical Nerve Disc Segmentation Using Circual Integro Differencial Operator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F16%3A00089230" target="_blank" >RIV/00216224:14110/16:00089230 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-24584-3_32" target="_blank" >http://dx.doi.org/10.1007/978-3-319-24584-3_32</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-24584-3_32" target="_blank" >10.1007/978-3-319-24584-3_32</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optical Nerve Disc Segmentation Using Circual Integro Differencial Operator
Popis výsledku v původním jazyce
The paper deals with design of suitable methodology for the detection of the optic nerve disc from ophthalmological images. This issue was frequently solved in the past based on the Hough transform. The problem is that some the clinical images lack of sufficient contrast and so it is difficult to identify individual objects in the images. In our analysis, we process the image data, which are poorly distinguishable. Another significant drawback is the lower resolution of the analyzed data, which leads to poor identification of the optic nerve disc. For the detection of the optic nerve disc is used integro differential operator, which is looking for objects in the image that have a circular shape. The advantage of this proposed solution is sufficient sensitivity even in the weaker contrast environment.
Název v anglickém jazyce
Optical Nerve Disc Segmentation Using Circual Integro Differencial Operator
Popis výsledku anglicky
The paper deals with design of suitable methodology for the detection of the optic nerve disc from ophthalmological images. This issue was frequently solved in the past based on the Hough transform. The problem is that some the clinical images lack of sufficient contrast and so it is difficult to identify individual objects in the images. In our analysis, we process the image data, which are poorly distinguishable. Another significant drawback is the lower resolution of the analyzed data, which leads to poor identification of the optic nerve disc. For the detection of the optic nerve disc is used integro differential operator, which is looking for objects in the image that have a circular shape. The advantage of this proposed solution is sufficient sensitivity even in the weaker contrast environment.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Computer and Communication Engineering Technology : Proceedings of ICOCOE 2015
ISBN
9783319245843
ISSN
1876-1119
e-ISSN
—
Počet stran výsledku
10
Strana od-do
387-396
Název nakladatele
Springer International Publishing
Místo vydání
Switzerland
Místo konání akce
Phuket
Datum konání akce
9. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—