Utilization of autologous superficial femoral vein graft in cases of infected prosthetic graft replacement and high infection-risk cases
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F19%3A00108562" target="_blank" >RIV/00216224:14110/19:00108562 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/19:00075949
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of autologous superficial femoral vein graft in cases of infected prosthetic graft replacement and high infection-risk cases
Popis výsledku v původním jazyce
Introduction: Aortic prosthetic graft infection is one of the most severe complications in vascular surgery. Good results are reported for the replacement using autologous superficial femoral vein (SFV) graft. This extensive procedure might be complicated by acute mesenteric ischemia (AMI). The aim of the study was to evaluate the safety of the procedure and options of early postoperative mesenteric ischemia detection. Methods: A retrospective review of 64 cases in which we have used autologous SFV graft was performed. The serum levels of biomarkers of AMI were assessed in comparison to 40 elective aortic surgery cases. Results: Average follow-up was 46.6 +/- 33.0 months, 30-day mortality was 6.3 %. The specificity of currently studied biomarkers of AMI (procalcitonin, ischemia modified albumin, I-FAPB2, and D-lactate) was low. Conclusions: Our results support the use of SFV graft for the treatment of aortic graft infection. Early postoperative detection of AMI remains challenging.
Název v anglickém jazyce
Utilization of autologous superficial femoral vein graft in cases of infected prosthetic graft replacement and high infection-risk cases
Popis výsledku anglicky
Introduction: Aortic prosthetic graft infection is one of the most severe complications in vascular surgery. Good results are reported for the replacement using autologous superficial femoral vein (SFV) graft. This extensive procedure might be complicated by acute mesenteric ischemia (AMI). The aim of the study was to evaluate the safety of the procedure and options of early postoperative mesenteric ischemia detection. Methods: A retrospective review of 64 cases in which we have used autologous SFV graft was performed. The serum levels of biomarkers of AMI were assessed in comparison to 40 elective aortic surgery cases. Results: Average follow-up was 46.6 +/- 33.0 months, 30-day mortality was 6.3 %. The specificity of currently studied biomarkers of AMI (procalcitonin, ischemia modified albumin, I-FAPB2, and D-lactate) was low. Conclusions: Our results support the use of SFV graft for the treatment of aortic graft infection. Early postoperative detection of AMI remains challenging.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-29701A" target="_blank" >NV17-29701A: Ischémií modifikovaný albumin a cirkulující mikroRNA jako nové technologie k monitorování tkáňové ischémie po cévních rekonstrukcích na břišní aortě</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů