Dlouhodobé výsledky totální náhrady kolenního kloubu P.F.C. Sigma s celopolyetylenovou tibiální komponentou
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F21%3A00127177" target="_blank" >RIV/00216224:14110/21:00127177 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.achot.cz/detail.php?stat=1238" target="_blank" >http://www.achot.cz/detail.php?stat=1238</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Dlouhodobé výsledky totální náhrady kolenního kloubu P.F.C. Sigma s celopolyetylenovou tibiální komponentou
Popis výsledku v původním jazyce
PURPOSE OF THE STUDY Use of an all-polyethylene (all-poly, AP) tibial component in primary total knee arthroplasty is still an attractive option considering the durability of replacement, the elimination of backside wear and the lower cost compared to modular metalbacked tibia. The purpose of the study was to evaluate the long-term results of the total knee replacement using the P.F.C. Sigma system with a monoblock all-polyethylene tibial component implanted at the 1st Orthopedic Department of the St. Anne's University Hospital and Masaryk University Brno in the period 1999-2010. MATERIAL AND METHODS In the monitored period, 911 total knee replacements using P.F.C. Sigma with an all-polyethylene tibial component were performed. This cohort of patients was evaluated at least 10 years after the primary replacement surgery. Altogether 323 knee replacements in 289 patients were evaluated. The clinical outcomes were assessed according to the Knee Society Clinical Rating System (KSS) and the Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. The replacement survival was evaluated using the Kaplan-Meier survival analysis. RESULTS In the evaluated group, the average KS was 82.6 points and the average functional score was 74.7 points. Excellent results were recorded in 213 cases, good results in 78 and satisfactory in 23 replacements. Poor clinical results were reported in 9 patients. The average range of motion was 105.8°. In 5 knees (1.5%) revision surgery was performed for infection complications, 3 cases were complicated due to periprosthetic fractures, 4 replacements were revised due to anterior knee pain and 8 knees showed a limited range of motion. Only 1 replacement was revised for aseptic loosening, with no need for reimplantation of the component. The survivorship of the implant was 98.5 % at the follow-up of 12.8 years, including the reasons of reimplantation. DISCUSSION Total knee replacement with an all-polyethylene tibial component is not so popular as the metal-backed modular implants. The all-polyethylene tibial component has certain advantages: lower unit costs, no backside wear, no liner dislocation, possibility of conservative bone resection. On the other hand, this type of implant is not modular and augmentations or longer stems cannot be used. Even though this type of endoprosthesis is recommended exclusively for elderly patients with a lower level of activity, the current mid- and long-term results show that indications for all-poly implants are much broader. CONCLUSIONS The total knee replacement with an all-polyethylene tibial component shows very good long-term clinical outcomes with an excellent survival rate. The all-poly design is cost-effective and may be used not only in elderly patients. Key words: total knee replacement, all-polyethylene tibial component, long-term results
Název v anglickém jazyce
Long-Term Results of Total Knee Replacement Using P.F.C. Sigma System with an All-Polyethylene Tibial Component
Popis výsledku anglicky
PURPOSE OF THE STUDY Use of an all-polyethylene (all-poly, AP) tibial component in primary total knee arthroplasty is still an attractive option considering the durability of replacement, the elimination of backside wear and the lower cost compared to modular metalbacked tibia. The purpose of the study was to evaluate the long-term results of the total knee replacement using the P.F.C. Sigma system with a monoblock all-polyethylene tibial component implanted at the 1st Orthopedic Department of the St. Anne's University Hospital and Masaryk University Brno in the period 1999-2010. MATERIAL AND METHODS In the monitored period, 911 total knee replacements using P.F.C. Sigma with an all-polyethylene tibial component were performed. This cohort of patients was evaluated at least 10 years after the primary replacement surgery. Altogether 323 knee replacements in 289 patients were evaluated. The clinical outcomes were assessed according to the Knee Society Clinical Rating System (KSS) and the Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. The replacement survival was evaluated using the Kaplan-Meier survival analysis. RESULTS In the evaluated group, the average KS was 82.6 points and the average functional score was 74.7 points. Excellent results were recorded in 213 cases, good results in 78 and satisfactory in 23 replacements. Poor clinical results were reported in 9 patients. The average range of motion was 105.8°. In 5 knees (1.5%) revision surgery was performed for infection complications, 3 cases were complicated due to periprosthetic fractures, 4 replacements were revised due to anterior knee pain and 8 knees showed a limited range of motion. Only 1 replacement was revised for aseptic loosening, with no need for reimplantation of the component. The survivorship of the implant was 98.5 % at the follow-up of 12.8 years, including the reasons of reimplantation. DISCUSSION Total knee replacement with an all-polyethylene tibial component is not so popular as the metal-backed modular implants. The all-polyethylene tibial component has certain advantages: lower unit costs, no backside wear, no liner dislocation, possibility of conservative bone resection. On the other hand, this type of implant is not modular and augmentations or longer stems cannot be used. Even though this type of endoprosthesis is recommended exclusively for elderly patients with a lower level of activity, the current mid- and long-term results show that indications for all-poly implants are much broader. CONCLUSIONS The total knee replacement with an all-polyethylene tibial component shows very good long-term clinical outcomes with an excellent survival rate. The all-poly design is cost-effective and may be used not only in elderly patients. Key words: total knee replacement, all-polyethylene tibial component, long-term results
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca
ISSN
0001-5415
e-ISSN
0001-5415
Svazek periodika
88
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
412-417
Kód UT WoS článku
000798817200002
EID výsledku v databázi Scopus
2-s2.0-85123651596