Real-World Data on the Usage of Hemopatch (R) as a Hemostat and Dural Sealant in Cranial and Spinal Neurosurgery
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F23%3A00131036" target="_blank" >RIV/00216224:14110/23:00131036 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.cureus.com/articles/121858-real-world-data-on-the-usage-of-hemopatch-as-a-hemostat-and-dural-sealant-in-cranial-and-spinal-neurosurgery#!/" target="_blank" >https://www.cureus.com/articles/121858-real-world-data-on-the-usage-of-hemopatch-as-a-hemostat-and-dural-sealant-in-cranial-and-spinal-neurosurgery#!/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.7759/cureus.34387" target="_blank" >10.7759/cureus.34387</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-World Data on the Usage of Hemopatch (R) as a Hemostat and Dural Sealant in Cranial and Spinal Neurosurgery
Popis výsledku v původním jazyce
Background and objectivesCerebrospinal fluid (CSF) leakage is a significant complication in cranial and spinal interventions. Hemostatic patches such as Hemopatch (R) are therefore used to support the watertight closure of the dura mater. Recently, we published the results of a large registry documenting the effectiveness and safety of Hemopatch (R) in various surgical specialties, including neurosurgery. Here we aimed to analyze the outcomes from the neurological/spinal cohort of this registry in more detail.MethodsBased on the data from the original registry, we performed a post hoc analysis for the neurological/spinal cohort. The Hemopatch (R) registry was designed as a prospective, multicenter, single-arm observational study. All surgeons were familiar with the application of Hemopatch (R) and it was used at the discretion of the responsible surgeon. The neurological/spinal cohort was open for patients of any age if they had received Hemopatch (R) during an open or minimally invasive cranial or spinal procedure. Patients with known hypersensitivity to bovine proteins or brilliant blue, intraoperative pulsatile severe bleeding, or an active infection at the potential target application site (TAS) were excluded from the registry. For the posthoc evaluation, we stratified the patients of the neurological/spinal cohort into two sub-cohorts: cranial and spinal. We collected information about the TAS, intraoperative achievement of watertight closure of the dura, and occurrence of postoperative CSF leaks.ResultsThe registry comprised 148 patients in the neurological/spinal cohort when enrolment was stopped. The dura was the application site for Hemopatch (R) in 147 patients (in one patient in the sacral region after tumor excision), of which 123 underwent a cranial procedure. Twenty-four patients underwent a spinal procedure. Intraoperatively, watertight closure was achieved in 130 patients (cranial sub-cohort: 119; spinal sub -cohort: 11). Postoperative CSF leakage occurred in 11 patients (cranial sub-cohort: nine; spinal sub-cohort: two). We observed no serious adverse events related to Hemopatch (R) .ConclusionOur post hoc analysis of real-world data from a European registry confirms the safe and effective use of Hemopatch (R) in neurosurgery, including cranial and spinal procedures, as also observed in some case series.
Název v anglickém jazyce
Real-World Data on the Usage of Hemopatch (R) as a Hemostat and Dural Sealant in Cranial and Spinal Neurosurgery
Popis výsledku anglicky
Background and objectivesCerebrospinal fluid (CSF) leakage is a significant complication in cranial and spinal interventions. Hemostatic patches such as Hemopatch (R) are therefore used to support the watertight closure of the dura mater. Recently, we published the results of a large registry documenting the effectiveness and safety of Hemopatch (R) in various surgical specialties, including neurosurgery. Here we aimed to analyze the outcomes from the neurological/spinal cohort of this registry in more detail.MethodsBased on the data from the original registry, we performed a post hoc analysis for the neurological/spinal cohort. The Hemopatch (R) registry was designed as a prospective, multicenter, single-arm observational study. All surgeons were familiar with the application of Hemopatch (R) and it was used at the discretion of the responsible surgeon. The neurological/spinal cohort was open for patients of any age if they had received Hemopatch (R) during an open or minimally invasive cranial or spinal procedure. Patients with known hypersensitivity to bovine proteins or brilliant blue, intraoperative pulsatile severe bleeding, or an active infection at the potential target application site (TAS) were excluded from the registry. For the posthoc evaluation, we stratified the patients of the neurological/spinal cohort into two sub-cohorts: cranial and spinal. We collected information about the TAS, intraoperative achievement of watertight closure of the dura, and occurrence of postoperative CSF leaks.ResultsThe registry comprised 148 patients in the neurological/spinal cohort when enrolment was stopped. The dura was the application site for Hemopatch (R) in 147 patients (in one patient in the sacral region after tumor excision), of which 123 underwent a cranial procedure. Twenty-four patients underwent a spinal procedure. Intraoperatively, watertight closure was achieved in 130 patients (cranial sub-cohort: 119; spinal sub -cohort: 11). Postoperative CSF leakage occurred in 11 patients (cranial sub-cohort: nine; spinal sub-cohort: two). We observed no serious adverse events related to Hemopatch (R) .ConclusionOur post hoc analysis of real-world data from a European registry confirms the safe and effective use of Hemopatch (R) in neurosurgery, including cranial and spinal procedures, as also observed in some case series.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
CUREUS JOURNAL OF MEDICAL SCIENCE
ISSN
2168-8184
e-ISSN
2168-8184
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
1-9
Kód UT WoS článku
000994470800052
EID výsledku v databázi Scopus
—