Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F24%3A00136410" target="_blank" >RIV/00216224:14110/24:00136410 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant
Popis výsledku v původním jazyce
Background: In a proband with idiopathic ventricular fibrillation (IF) and in his sister suffering from catecholaminergic polymorphic ventricular tachycardia (CPVT), p.Y4734C-RYR2 variant was found. Here we bring data showing the spontaneous electrical activity of cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CM) of the proband (IF), his sister (CPVT), and his healthy nephew as control (WT), and its changes under arrhythmogenic conditions. Methods: The recordings by the multielectrode array technique were performed in control, i.e. in Tyrode solution with 5 mM K+ (5K++37°C), in 0.5 µM isoprenaline (ISO), and under cumulatively added hypokalemia (3K+), β-adrenergic stimulation (ISO), and hyperthermia (40°C). Considering non-normal data distribution, the cycle length (CL) and its short-term variability (STVCL) are shown as the median from n samples and non-parametric tests were used. Results: In 5K+, CPVT hiPSC-CM had a significantly longer CL (1.47 s, n=19; P˂0.05) than IF (1.05 s, n=32) and WT (0.77 s, n=7). ISO significantly shortened CL in all groups (by 38.3, 22.7, and 17.7 % in CPVT, IF, and WT, respectively, n=19, 32, and 7; P ˂ 0.05) and CPVT showed a significantly larger reaction than IF (P˂0.05). The arrhythmogenic factors caused a significant increment in STVCL in IF (41.91 in 3K+, 22.65 in 3K++ISO, and 65.38 ms in 3K++ISO+40°C, vs. 10.23 ms in control; n=24; P˂0.05) whereas it was significantly increased only in 3K+ in CPVT (21.14, 15.99, and 10.44 ms, respectively, vs. 13.13 in control; n=20; P˂0.05). IF and CPVT significantly differed in STVCL in 3K++ISO+40°C. Conclusions: CPVT hiPSC-CM showed a lower frequency of spontaneous activity and its higher reactivity to ISO. An increment in beat-to-beat variability of CL was observed during arrhythmogenic conditions in IF hiPSC-CM.
Název v anglickém jazyce
Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant
Popis výsledku anglicky
Background: In a proband with idiopathic ventricular fibrillation (IF) and in his sister suffering from catecholaminergic polymorphic ventricular tachycardia (CPVT), p.Y4734C-RYR2 variant was found. Here we bring data showing the spontaneous electrical activity of cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CM) of the proband (IF), his sister (CPVT), and his healthy nephew as control (WT), and its changes under arrhythmogenic conditions. Methods: The recordings by the multielectrode array technique were performed in control, i.e. in Tyrode solution with 5 mM K+ (5K++37°C), in 0.5 µM isoprenaline (ISO), and under cumulatively added hypokalemia (3K+), β-adrenergic stimulation (ISO), and hyperthermia (40°C). Considering non-normal data distribution, the cycle length (CL) and its short-term variability (STVCL) are shown as the median from n samples and non-parametric tests were used. Results: In 5K+, CPVT hiPSC-CM had a significantly longer CL (1.47 s, n=19; P˂0.05) than IF (1.05 s, n=32) and WT (0.77 s, n=7). ISO significantly shortened CL in all groups (by 38.3, 22.7, and 17.7 % in CPVT, IF, and WT, respectively, n=19, 32, and 7; P ˂ 0.05) and CPVT showed a significantly larger reaction than IF (P˂0.05). The arrhythmogenic factors caused a significant increment in STVCL in IF (41.91 in 3K+, 22.65 in 3K++ISO, and 65.38 ms in 3K++ISO+40°C, vs. 10.23 ms in control; n=24; P˂0.05) whereas it was significantly increased only in 3K+ in CPVT (21.14, 15.99, and 10.44 ms, respectively, vs. 13.13 in control; n=20; P˂0.05). IF and CPVT significantly differed in STVCL in 3K++ISO+40°C. Conclusions: CPVT hiPSC-CM showed a lower frequency of spontaneous activity and its higher reactivity to ISO. An increment in beat-to-beat variability of CL was observed during arrhythmogenic conditions in IF hiPSC-CM.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NU22-02-00348" target="_blank" >NU22-02-00348: Funkční hodnocení genetických variant u případů klinicky „skutečné“ idiopatické fibrilace komor: in vitro a in silico modelování s cílem odhalit arytmogenní mechanismus</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů