Calibration graphs for steels by IR laser ablation inductively coupled plasma atomic emission spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F01%3A00004314" target="_blank" >RIV/00216224:14310/01:00004314 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
anglicky
Popis výsledku v původním jazyce
Infrared laser ablation (IR-LA) was studied as a sample introduction technique for the analysis of steels by inductively coupled plasma atomic emission spectrometry (ICP-AES).A comparison of two IR-LA-ICP-AES systems based on Q-switched nanosecond Nd:YAGlasers was performed. The beam of the Lina-SPARK Atomizer (LSA Sarl, Cully, Switzerland) based on the Surelite I-20 laser (Continuum, USA) was moved along a circle. A Perkin-Elmer Optima 3000 DV ICP system was used for emission measurement both with lateral and axial viewing modes. A laboratory-made ablation system based on the Brilliant laser (Quantel) was coupled to a Jobin-Yvon 170 Ultrace ICP (lateral viewing, polychromator part employed). A sample was rotated along a circle during ablation. Linearity of calibration plots was verified at least up to 19 % Cr and 12 % Ni without internal standardization for both LA-ICP-AES systems. Other elements were examined up to 3 % Mo, 1.5 % Mn, 1.7 % Si and 0.15 % Cu. The reproducibility was in
Název v anglickém jazyce
anglicky
Popis výsledku anglicky
Infrared laser ablation (IR-LA) was studied as a sample introduction technique for the analysis of steels by inductively coupled plasma atomic emission spectrometry (ICP-AES).A comparison of two IR-LA-ICP-AES systems based on Q-switched nanosecond Nd:YAGlasers was performed. The beam of the Lina-SPARK Atomizer (LSA Sarl, Cully, Switzerland) based on the Surelite I-20 laser (Continuum, USA) was moved along a circle. A Perkin-Elmer Optima 3000 DV ICP system was used for emission measurement both with lateral and axial viewing modes. A laboratory-made ablation system based on the Brilliant laser (Quantel) was coupled to a Jobin-Yvon 170 Ultrace ICP (lateral viewing, polychromator part employed). A sample was rotated along a circle during ablation. Linearity of calibration plots was verified at least up to 19 % Cr and 12 % Ni without internal standardization for both LA-ICP-AES systems. Other elements were examined up to 3 % Mo, 1.5 % Mn, 1.7 % Si and 0.15 % Cu. The reproducibility was in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fresenius Journal of Analytical Chemistry
ISSN
0937-0633
e-ISSN
—
Svazek periodika
370
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
387
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—