Metallothionein (MT) from rabbit liver was analysed by differential pulse polarography (DPP with DME), cyclic voltammetry (CV), square wave voltammetry (SWV), and chronopotentiometric stripping analysis (CPSA) with hanging mercury drop electrode (HMDE) under various conditions. The highest sensitivity of the MT determination was obtained with CPSA which produced a well developed peak H due to catalytic hydrogen evolution at highly negative potentials. The highest peak H was obtained in borate buffer atpH 7.6. In this medium subnanomolar concentrations of MT were detectable. In the adsorptive transfer stripping (medium exchange) experiments determination of few femtomoles of MT in 5 ml aliquots of the analyte was possible. CPSA determination of MT in various tissues of carp (Cyprinus cyprio) yielded values in agreement with the published data.
Název v anglickém jazyce
Determination of Metallothionein at Femtomole Level by Constant Current Stripping Chronopotentiometry
Popis výsledku anglicky
Metallothionein (MT) from rabbit liver was analysed by differential pulse polarography (DPP with DME), cyclic voltammetry (CV), square wave voltammetry (SWV), and chronopotentiometric stripping analysis (CPSA) with hanging mercury drop electrode (HMDE) under various conditions. The highest sensitivity of the MT determination was obtained with CPSA which produced a well developed peak H due to catalytic hydrogen evolution at highly negative potentials. The highest peak H was obtained in borate buffer atpH 7.6. In this medium subnanomolar concentrations of MT were detectable. In the adsorptive transfer stripping (medium exchange) experiments determination of few femtomoles of MT in 5 ml aliquots of the analyte was possible. CPSA determination of MT in various tissues of carp (Cyprinus cyprio) yielded values in agreement with the published data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV204%2F97%2FK084" target="_blank" >GV204/97/K084: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Anal. Chem.
ISSN
0003-2700
e-ISSN
—
Svazek periodika
2001
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
4801
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—