Electrochemical impedance spectroscopy of polynucleotides.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F01%3A00007530" target="_blank" >RIV/00216224:14310/01:00007530 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical impedance spectroscopy of polynucleotides.
Popis výsledku v původním jazyce
The dependence of the impedance of the electrode double layer of mercury electrode on frequency around the potentials of the tensammetric peaks of single-stranded and double-helical polynucleotides and DNA was studied. From the frequency dependence of the impedance of the electrode double layer represented in a complex impedance plot (the imaginary component Z'' is plotted against the real component Z', Cole-Cole or Nyquist plot) the electric equivalent circuit of the electrode covered with adsorbed DNAlayer was determined. It was concluded the desorption of denatured ssDNA is accompanied by higher dielectric losses than the desorption of native dsDNA. This can be explained by the higher flexibility of ssDNA compared to the dsDNA. The capacitance peakof single stranded poly A observed at pH 8 around -1.3 V splits at low frequencies in two peaks.
Název v anglickém jazyce
Electrochemical impedance spectroscopy of polynucleotides.
Popis výsledku anglicky
The dependence of the impedance of the electrode double layer of mercury electrode on frequency around the potentials of the tensammetric peaks of single-stranded and double-helical polynucleotides and DNA was studied. From the frequency dependence of the impedance of the electrode double layer represented in a complex impedance plot (the imaginary component Z'' is plotted against the real component Z', Cole-Cole or Nyquist plot) the electric equivalent circuit of the electrode covered with adsorbed DNAlayer was determined. It was concluded the desorption of denatured ssDNA is accompanied by higher dielectric losses than the desorption of native dsDNA. This can be explained by the higher flexibility of ssDNA compared to the dsDNA. The capacitance peakof single stranded poly A observed at pH 8 around -1.3 V splits at low frequencies in two peaks.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts, XVI th International Symposium on Bioelectrochemistry and Bioenergetics
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
110
Název nakladatele
XVI th International Symposium on Bioelectrochemistry and Bioenergetics
Místo vydání
Bratislava
Místo konání akce
1.-6.6.2001, Bratislava
Datum konání akce
—
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—