Silver Electrode as a Sensor for Determination of Zinc in Cell Cultivation Medium
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F02%3A00005423" target="_blank" >RIV/00216224:14310/02:00005423 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Silver Electrode as a Sensor for Determination of Zinc in Cell Cultivation Medium
Popis výsledku v původním jazyce
Use of the silver electrode as a sensor for monitoring of zinc in cell growth medium is described. Zinc at siver electrodes provides specific voltammetric signal, which is affected by solution components. Signlas of zinc ions in phosphate buffer solutions with and without cell growth meidum were compared. Common DMEM cell culture medium was used for the cultivation of a cell line of v-myb-transformed chicken monoblasts and its variants expressing v-jun and c-jun in a zinc dependent manner. Electrochemical results showed zinc concentrations in the medium coincide very well with the jun expression. With respect to the low toxicity of xilver for eukaryotic cells, silver electrodes represent promising tools for the determination of zinc concentrations in vivo without the potential risk of a cell culture damage.
Název v anglickém jazyce
Silver Electrode as a Sensor for Determination of Zinc in Cell Cultivation Medium
Popis výsledku anglicky
Use of the silver electrode as a sensor for monitoring of zinc in cell growth medium is described. Zinc at siver electrodes provides specific voltammetric signal, which is affected by solution components. Signlas of zinc ions in phosphate buffer solutions with and without cell growth meidum were compared. Common DMEM cell culture medium was used for the cultivation of a cell line of v-myb-transformed chicken monoblasts and its variants expressing v-jun and c-jun in a zinc dependent manner. Electrochemical results showed zinc concentrations in the medium coincide very well with the jun expression. With respect to the low toxicity of xilver for eukaryotic cells, silver electrodes represent promising tools for the determination of zinc concentrations in vivo without the potential risk of a cell culture damage.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV204%2F97%2FK084" target="_blank" >GV204/97/K084: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Biochemistry
ISSN
0003-2697
e-ISSN
—
Svazek periodika
301
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
8
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—