Application of carbon electrodes modified with a mercury layer of a different thickness for studies of the adsorption and kinetics of phase transients of cytidine.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F02%3A00007358" target="_blank" >RIV/00216224:14310/02:00007358 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of carbon electrodes modified with a mercury layer of a different thickness for studies of the adsorption and kinetics of phase transients of cytidine.
Popis výsledku v původním jazyce
The kinetics of phase transients of cytidine adsorbed at pyrolytic graphite electrodes, glassy caron electrodes, and the same electrodes modified with a mercury layer (mercury film electrodes)was studied by chronoamperometry (j-t curves and capacitance measurements (C-t curves). In acidic solution (pH 5) the two-dimensional condensation of adsorbed cytidine molecules and formation of a compact layer takes place only in one potential region. In alkaline solution (pH 8.3) cytidine forms two different physisorbed condensed layers at the mercury film electrodes. The phase trasients between the dilute and compact cytidine layers are about three times faster in acid solution than in alkaline solution. As long as the thickness of the mercury layer was greaterthan 2um, pronounced current maxima characteristic for the nucleation process were observed on j-t curves during phase transients between dilute and compact layers.
Název v anglickém jazyce
Application of carbon electrodes modified with a mercury layer of a different thickness for studies of the adsorption and kinetics of phase transients of cytidine.
Popis výsledku anglicky
The kinetics of phase transients of cytidine adsorbed at pyrolytic graphite electrodes, glassy caron electrodes, and the same electrodes modified with a mercury layer (mercury film electrodes)was studied by chronoamperometry (j-t curves and capacitance measurements (C-t curves). In acidic solution (pH 5) the two-dimensional condensation of adsorbed cytidine molecules and formation of a compact layer takes place only in one potential region. In alkaline solution (pH 8.3) cytidine forms two different physisorbed condensed layers at the mercury film electrodes. The phase trasients between the dilute and compact cytidine layers are about three times faster in acid solution than in alkaline solution. As long as the thickness of the mercury layer was greaterthan 2um, pronounced current maxima characteristic for the nucleation process were observed on j-t curves during phase transients between dilute and compact layers.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electroanalytical Chemistry
ISSN
0022-0728
e-ISSN
—
Svazek periodika
536
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
17
Strana od-do
19
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—