Studium hloubkových profilů pozinkovaných plechů metodami LA-ICP-MS, LA-ICP-OES a LIBS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F04%3A00010232" target="_blank" >RIV/00216224:14310/04:00010232 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Depth profile studies of Zn-coated sheets by LA-ICP-MS, LA-ICP-OES and LIBS
Popis výsledku v původním jazyce
For coatings and layers of thickness between tens of nm and tens of mm, the glow discharge optical emission spectrometry (GD-OES), is currently employed for quantitative depth profiling. Laser ablation (LA) combined with ICP-MS or as an emission source for laser-induced breakdown spectroscopy (LIBS) might be useful tool for the depth profile analysis of coatings with thickness in the range from units to tens of micrometers. However, depth resolution might be deteriorated due to a too large ablation depth per laser shot, a non-uniform radial energy distribution (Gaussian) in the laser beam, and rugosity at the bottom of the crater. Zinc-coated iron sheets (hot dipped and galvanically coated) of thickness between 6 an 30 um were studied by means of LA-ICP-MS system [1]consisting of a homogenized 193 nm ArF* laser ablation system (GeoLas, Microlas, Göttingen, Germany) coupled to an ICP-QMS Agilent 7500 (Agilent Technologies, USA). The sample in the ablation cell can be observed during abl
Název v anglickém jazyce
Depth profile studies of Zn-coated sheets by LA-ICP-MS, LA-ICP-OES and LIBS
Popis výsledku anglicky
For coatings and layers of thickness between tens of nm and tens of mm, the glow discharge optical emission spectrometry (GD-OES), is currently employed for quantitative depth profiling. Laser ablation (LA) combined with ICP-MS or as an emission source for laser-induced breakdown spectroscopy (LIBS) might be useful tool for the depth profile analysis of coatings with thickness in the range from units to tens of micrometers. However, depth resolution might be deteriorated due to a too large ablation depth per laser shot, a non-uniform radial energy distribution (Gaussian) in the laser beam, and rugosity at the bottom of the crater. Zinc-coated iron sheets (hot dipped and galvanically coated) of thickness between 6 an 30 um were studied by means of LA-ICP-MS system [1]consisting of a homogenized 193 nm ArF* laser ablation system (GeoLas, Microlas, Göttingen, Germany) coupled to an ICP-QMS Agilent 7500 (Agilent Technologies, USA). The sample in the ablation cell can be observed during abl
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VS97020" target="_blank" >VS97020: Laboratoř plazmových zdrojů pro chemickou analýzu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
11th Solid Sampling Colloquium with Atomic Spectrometry
ISBN
963 9319 38 4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
19-19
Název nakladatele
G. Galbacs
Místo vydání
Budapest
Místo konání akce
Balatonfoldvar, Hungary
Datum konání akce
27. 6. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—