Studium fluorescenčně značených peptidů a malých proteinů pomocí kapilární elektroforézy s laserem indukovanou detekcí kombinovanou s hmotnostní spektrometrií MALDI.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00012704" target="_blank" >RIV/00216224:14310/05:00012704 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection
Popis výsledku v původním jazyce
In this work, we apply CE-LIF, CE-UV and CE - Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI TOFMS) to investigate derivatization of model peptides and small proteins with rhodamine-based fluorescent reagents, which are compatible with the wavelength of frequency doubled diode pumped Nd:YAG excitation laser (532 nm). While the LIF detection mode is needed for sensitive detection, the MALDI TOFMS analysis can reveal the mass of analytes. Both derivatized and non-derivatized peptides and proteins, the number of fluorescent labels per peptide/proteins and other product of derivatization process can be detected directly from reaction mixtures or after separation. Thus, MALDI TOFMS serves for additional identification ofpeaks present in CELIF or CEUV electropherograms. For off-line coupling of CE with MALDI MS, subatmospheric deposition interface was used. An examples of final sensitive CELIF separation of derivatized peptides and small proteins are giv
Název v anglickém jazyce
Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection
Popis výsledku anglicky
In this work, we apply CE-LIF, CE-UV and CE - Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI TOFMS) to investigate derivatization of model peptides and small proteins with rhodamine-based fluorescent reagents, which are compatible with the wavelength of frequency doubled diode pumped Nd:YAG excitation laser (532 nm). While the LIF detection mode is needed for sensitive detection, the MALDI TOFMS analysis can reveal the mass of analytes. Both derivatized and non-derivatized peptides and proteins, the number of fluorescent labels per peptide/proteins and other product of derivatization process can be detected directly from reaction mixtures or after separation. Thus, MALDI TOFMS serves for additional identification ofpeaks present in CELIF or CEUV electropherograms. For off-line coupling of CE with MALDI MS, subatmospheric deposition interface was used. An examples of final sensitive CELIF separation of derivatized peptides and small proteins are giv
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F03%2F0515" target="_blank" >GA203/03/0515: Integrovaná analýza genomu a proteomu terapeuticky významných bakteriofágů kombinací elektroforézy a hmotnostní spektrometrie</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Collection Symposium Series, Biollogicaly Active Peptides
ISBN
80-86241-26-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
103-106
Název nakladatele
Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic
Místo vydání
Praha
Místo konání akce
Praha, ÚOCHB AVČR
Datum konání akce
20. 4. 2005
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—