Amperometrické sítotisková biosensorová pole s koimobilisovanými oxidoreduktasami a cholinesterasami
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00013673" target="_blank" >RIV/00216224:14310/05:00013673 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases
Popis výsledku v původním jazyce
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiosedehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx).All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates
Název v anglickém jazyce
Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases
Popis výsledku anglicky
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiosedehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx).All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
528
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
9-19