Chromatografická separace polycyklických aromatických dusíkatých heterocyklů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00014632" target="_blank" >RIV/00216224:14310/05:00014632 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chromatogrphic Separation of Polycyclic Aromatic Nitrogen Heterocycles
Popis výsledku v původním jazyce
Potential of reverse phase - high performance liquid chromatography (RP-HPLC) for separation and determination of polycyclic aromatic nitrogen heterocycles (PANHs) is discussed. Effect of acetonitrile/buffer mobile phase composition on retention behaviour of individual analytes on C18 stationary phases was investigated, to find a suitable conditions for separation of PANHs in a mixture with some other polycyclic aromatic compounds (e.g. PAH). The large variability in mobile phase composition allows effective properties controlling of RP-HPLC determination of PANHs in particular samples. Low limits of detection (LODs) obtained for individual PANHs using two detection techniques (UV-DAD and FD) indicate the possibility to use the method as an alternativemethod of determination of PANHs in environmental samples. The comparison with other methods of PANHs determination is presented.
Název v anglickém jazyce
Chromatogrphic Separation of Polycyclic Aromatic Nitrogen Heterocycles
Popis výsledku anglicky
Potential of reverse phase - high performance liquid chromatography (RP-HPLC) for separation and determination of polycyclic aromatic nitrogen heterocycles (PANHs) is discussed. Effect of acetonitrile/buffer mobile phase composition on retention behaviour of individual analytes on C18 stationary phases was investigated, to find a suitable conditions for separation of PANHs in a mixture with some other polycyclic aromatic compounds (e.g. PAH). The large variability in mobile phase composition allows effective properties controlling of RP-HPLC determination of PANHs in particular samples. Low limits of detection (LODs) obtained for individual PANHs using two detection techniques (UV-DAD and FD) indicate the possibility to use the method as an alternativemethod of determination of PANHs in environmental samples. The comparison with other methods of PANHs determination is presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemické Listy
ISSN
0009-2770
e-ISSN
—
Svazek periodika
roč. 99
Číslo periodika v rámci svazku
99(s)
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
163-165
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—