Analýza tkání z hrabošů krmených bromadiolonem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F06%3A00015746" target="_blank" >RIV/00216224:14310/06:00015746 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An analysis of tissues of vertebrates treated by Bromadiolone
Popis výsledku v původním jazyce
Bromadiolone is a 4-hydroxy-coumarine derivative used as rodenticide, which shows an anticoagulant effect based on the prothrombine synthesis inhibition. The determination of this compound has interest in toxicological analysis owing to its high accute oral toxicity. The dose of bromadiolone, which is expected to cause death of 50 % of male rats by oral administration (LD50) is 1.125 mg.kg-1. A determination of this compound of interest has also interest in environmental analysis taking into account itswide use to control rodent populations, which involves the resulting risk of water pollution or intoxication of non-target species. Thus we focused on suggesting of a new technique for determination of bromadiolone using high-performance liquid chromatography with electrochemical detection (HPLC-ED). Prior to analysis in flow system we have studied the basic electrochemical behaviour of bromadiolone by cyclic voltammetry on Autolab analyser (EcoChemie, Netherlands) connected with VA-Sta
Název v anglickém jazyce
An analysis of tissues of vertebrates treated by Bromadiolone
Popis výsledku anglicky
Bromadiolone is a 4-hydroxy-coumarine derivative used as rodenticide, which shows an anticoagulant effect based on the prothrombine synthesis inhibition. The determination of this compound has interest in toxicological analysis owing to its high accute oral toxicity. The dose of bromadiolone, which is expected to cause death of 50 % of male rats by oral administration (LD50) is 1.125 mg.kg-1. A determination of this compound of interest has also interest in environmental analysis taking into account itswide use to control rodent populations, which involves the resulting risk of water pollution or intoxication of non-target species. Thus we focused on suggesting of a new technique for determination of bromadiolone using high-performance liquid chromatography with electrochemical detection (HPLC-ED). Prior to analysis in flow system we have studied the basic electrochemical behaviour of bromadiolone by cyclic voltammetry on Autolab analyser (EcoChemie, Netherlands) connected with VA-Sta
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP525%2F04%2FP132" target="_blank" >GP525/04/P132: Studium obranných mechanismů rostlin při stresu způsobeném těžkými kovy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Toxcon 2006; 11. Interdisciplinary Slovak - Czech Toxicological Conference
ISBN
80-969474-1-9
ISSN
—
e-ISSN
—
Počet stran výsledku
300
Strana od-do
39-39
Název nakladatele
Slovak Toxicology Society SETOX
Místo vydání
Trencianske Teplice
Místo konání akce
Trencianske Teplice
Datum konání akce
5. 6. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—