Studium redoxnich procesů na polimerem modifikované screen printed elektrodě s využitím eliminační voltametrie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00019385" target="_blank" >RIV/00216224:14310/07:00019385 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of redox processes on polymeric modified screen printed electrode using elimination voltammetry
Popis výsledku v původním jazyce
In the last time various new modified electrodes were developed and used as DNA biosensors. One of the general knowledge is focused on new types of screen-printed electrodes (SPE). Due to their specific behavior and ultimate applications as biosensors, the characterization of surfaces of SPE and the electrochemical processes speak on these electrodes need to be conceived. Besides common electrochemical methods the elimination voltammetry with linear scan (EVLS) is able to contribute to the electrochemical study of SPE features. The EVLS can be considered as a mathematical model utilizing linear sweep or cyclic voltammetry results to eliminate some selected particular currents from total voltammetric current and therefore it is capable to discover the rate determining step process or to characterize the influence of modified electrode surface on electrode processes. The elimination of selected particular currents and conservation the other ones is achieved by an elimination function for
Název v anglickém jazyce
Study of redox processes on polymeric modified screen printed electrode using elimination voltammetry
Popis výsledku anglicky
In the last time various new modified electrodes were developed and used as DNA biosensors. One of the general knowledge is focused on new types of screen-printed electrodes (SPE). Due to their specific behavior and ultimate applications as biosensors, the characterization of surfaces of SPE and the electrochemical processes speak on these electrodes need to be conceived. Besides common electrochemical methods the elimination voltammetry with linear scan (EVLS) is able to contribute to the electrochemical study of SPE features. The EVLS can be considered as a mathematical model utilizing linear sweep or cyclic voltammetry results to eliminate some selected particular currents from total voltammetric current and therefore it is capable to discover the rate determining step process or to characterize the influence of modified electrode surface on electrode processes. The elimination of selected particular currents and conservation the other ones is achieved by an elimination function for
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků VII. Pracovního setkání fyzikálních chemiků a elektrochemiků
ISBN
978-80-210-4235-3
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
44-45
Název nakladatele
Masarykova universita
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
29. 1. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—