Laserová ablace pro přímou analýzu karbidů wolframu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00023746" target="_blank" >RIV/00216224:14310/07:00023746 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laser ablation for direct analysis of tungsten carbides
Popis výsledku v původním jazyce
The possibility of direct determination of Co, Nb, Ta and Ti in WC/Co cemented materials by different methods of laser ablation (LA-ICP-OES/MS, LIBS) has been studied. Using systems with higher laser wavelengths, fractionation occurred. The problem of fractionation arose especially in case of cobalt as an element with low melting and boiling temperature (1495stC and 2927stC) and different linkage in hard-metal samples comparing with other elements of interest. Signal vs. content dependences constructedfor each element and each method show best correlation coefficients for LA-ICP-MS method using Nd:YAG @213 nm laser. Described LA-ICP-MS method is suitable for determination of mentioned analytes with repeatability up to 8% RSD. LIBS method using excimerlaser is suitable for determination of Nb, Ta and Ti with repeatability up to 10% RSD. For Co determination using LIBS, only semiquntitative estimation is possible.
Název v anglickém jazyce
Laser ablation for direct analysis of tungsten carbides
Popis výsledku anglicky
The possibility of direct determination of Co, Nb, Ta and Ti in WC/Co cemented materials by different methods of laser ablation (LA-ICP-OES/MS, LIBS) has been studied. Using systems with higher laser wavelengths, fractionation occurred. The problem of fractionation arose especially in case of cobalt as an element with low melting and boiling temperature (1495stC and 2927stC) and different linkage in hard-metal samples comparing with other elements of interest. Signal vs. content dependences constructedfor each element and each method show best correlation coefficients for LA-ICP-MS method using Nd:YAG @213 nm laser. Described LA-ICP-MS method is suitable for determination of mentioned analytes with repeatability up to 8% RSD. LIBS method using excimerlaser is suitable for determination of Nb, Ta and Ti with repeatability up to 10% RSD. For Co determination using LIBS, only semiquntitative estimation is possible.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Hutní a průmyslová analytika 2007
ISBN
978-80-86380-38-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
45-50
Název nakladatele
Václav Helán
Místo vydání
Česká Těšín
Místo konání akce
Ledeč nad Sázavou
Datum konání akce
1. 1. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—