LIBS and LA-ICP-MS Complementary Study of Elemental Distributions in Biominerals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F08%3A00026783" target="_blank" >RIV/00216224:14310/08:00026783 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LIBS and LA-ICP-MS Complementary Study of Elemental Distributions in Biominerals
Popis výsledku v původním jazyce
Two Q-switched Nd:YAG lasers (UP-266 MACRO-New Wave and Quantel Brilliant) operated at fourth harmonic frequency (266 nm) and at the fundamental wavelength of 1064 nm, respectively, were used in our double pulse experiments. The laser-induced plasma radiation was transported by a fiber optic system onto the entrance slit of a monochromator (Jobin Yvon TRIAX 320) with ICCD detector (Jobin Yvon Horiba). LA-ICP-MS technique is based on the transport of the dry aerosol formed during laser ablation to next excitation/ionization source (ICP). Recently LA-ICP-MS has increasingly been used to quantify trace elements with a high spatial lateral resolution and low limits of detection in many different materials, including industrial materials, geological samplesand human remains.
Název v anglickém jazyce
LIBS and LA-ICP-MS Complementary Study of Elemental Distributions in Biominerals
Popis výsledku anglicky
Two Q-switched Nd:YAG lasers (UP-266 MACRO-New Wave and Quantel Brilliant) operated at fourth harmonic frequency (266 nm) and at the fundamental wavelength of 1064 nm, respectively, were used in our double pulse experiments. The laser-induced plasma radiation was transported by a fiber optic system onto the entrance slit of a monochromator (Jobin Yvon TRIAX 320) with ICCD detector (Jobin Yvon Horiba). LA-ICP-MS technique is based on the transport of the dry aerosol formed during laser ablation to next excitation/ionization source (ICP). Recently LA-ICP-MS has increasingly been used to quantify trace elements with a high spatial lateral resolution and low limits of detection in many different materials, including industrial materials, geological samplesand human remains.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME08002" target="_blank" >ME08002: Použití spektroskopie laserem buzeného plazmatu (LIBS) a laserové ablace ve spojení s ICP-OES/MS spektroskopií pro chemické mapování biominerálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů