Kombinovaný 3v1 fotometrický, fluorimetrický a bezkontaktní vodivostní detektor pro kapilární separace: Aplikace pro simultání stanovení v CE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F08%3A00026862" target="_blank" >RIV/00216224:14310/08:00026862 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Combined 3-in-1 photometric, fluorimetric and contactless conductometric on-capillary detector for capillary separations: Applicability for simultaneous detection in CE
Popis výsledku v původním jazyce
A new design of on-capillary detection combining 3 detection modes - photometric (PD), fluorimetric (FD) and contactless conductivity (C4D) - in one identical point of detection has been recently introduced, tested and characterised. This design allows acombined 3-in-1 detection in capillary separation techniques (CE, CEC, capillary- and nano-LC). A key advantage is the concurrent availability of the three independent on-column detection techniques in the same point, thus avoiding undesirable shifts inseparation times caused by multiple parallel detectors. The per-definition concurrent availability of all the 3 detection modes (PD, FD, C4D) offers another unique advantage for the analysis of complex samples, where each of the single detection modes alone might yield an incomplete detection of the present analytes.
Název v anglickém jazyce
Combined 3-in-1 photometric, fluorimetric and contactless conductometric on-capillary detector for capillary separations: Applicability for simultaneous detection in CE
Popis výsledku anglicky
A new design of on-capillary detection combining 3 detection modes - photometric (PD), fluorimetric (FD) and contactless conductivity (C4D) - in one identical point of detection has been recently introduced, tested and characterised. This design allows acombined 3-in-1 detection in capillary separation techniques (CE, CEC, capillary- and nano-LC). A key advantage is the concurrent availability of the three independent on-column detection techniques in the same point, thus avoiding undesirable shifts inseparation times caused by multiple parallel detectors. The per-definition concurrent availability of all the 3 detection modes (PD, FD, C4D) offers another unique advantage for the analysis of complex samples, where each of the single detection modes alone might yield an incomplete detection of the present analytes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2008 5th international interdisciplinary meeting on bioanalysis
ISBN
978-80-254-3194-8
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Institute of Analytical Chemistry AS CR v.v.i
Místo vydání
Brno, Česká Rapublika
Místo konání akce
Brno, Česká Rapublika
Datum konání akce
24. 11. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce