Dvoupulzní laserová ablace a plazma: časově rozlišená spektrometrie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F08%3A00027005" target="_blank" >RIV/00216224:14310/08:00027005 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Double pulse laser ablation and plasma: time resolved spectral measurements
Popis výsledku v původním jazyce
Most of the studies on double-pulse LIBS have been performed using an intensified CCD (ICCD) detection. Using ICCD, spectral information over wide range can be recorded on each laser pulse. Besides ICCD, also photomultipliers (PMT) can be used to monitorsingle emission lines. The output of the PMT is a current proportional to the intensity of the incident light. PMTs are not integrating devices as they provide a signal simultaneous in time with the incident light intensity. The combination of ICCD andPMT can be useful to determine both, the spectral and time resolved plasma emission. In this study, we present orthogonal re-heating double pulse experimental system equipped with both ICCD and PMT detection and preliminary measurements of temperatures of plasmas generated on an iron sample.
Název v anglickém jazyce
Double pulse laser ablation and plasma: time resolved spectral measurements
Popis výsledku anglicky
Most of the studies on double-pulse LIBS have been performed using an intensified CCD (ICCD) detection. Using ICCD, spectral information over wide range can be recorded on each laser pulse. Besides ICCD, also photomultipliers (PMT) can be used to monitorsingle emission lines. The output of the PMT is a current proportional to the intensity of the incident light. PMTs are not integrating devices as they provide a signal simultaneous in time with the incident light intensity. The combination of ICCD andPMT can be useful to determine both, the spectral and time resolved plasma emission. In this study, we present orthogonal re-heating double pulse experimental system equipped with both ICCD and PMT detection and preliminary measurements of temperatures of plasmas generated on an iron sample.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME08002" target="_blank" >ME08002: Použití spektroskopie laserem buzeného plazmatu (LIBS) a laserové ablace ve spojení s ICP-OES/MS spektroskopií pro chemické mapování biominerálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
CHEMICKÉ LISTY
ISSN
0009-2770
e-ISSN
—
Svazek periodika
102
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—