Substrate-assisted laser desorption inductively-coupled plasma mass spectrometry for determination of copper in myeloid leukemia cells
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F10%3A00043957" target="_blank" >RIV/00216224:14310/10:00043957 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Substrate-assisted laser desorption inductively-coupled plasma mass spectrometry for determination of copper in myeloid leukemia cells
Popis výsledku v původním jazyce
This work presents a detailed characterization of substrate-assisted laser desorption inductively coupled plasma mass spectrometry (SALD ICP-MS), a new approach in the determination of trace elements in submicrolitre volumes. SALD ICP-MS allows quantitative analysis of metals in liquid samples with defined volumes deposited onto an absorbing substrate due to complete sample desorption at relatively low laser power density. Analysis of model samples of Cu(II) showed a constant signal over a wide range oflaser power density, an independence of signal on desorption modes and a wide linear dynamic range. SALD ICP-MS with its limit of detection for copper below 26 fg in submicrolitre samples was successfully applied to investigate cytotoxic effects of disulfiram in human myeloid leukemia cells U937 depending on intracellular levels of copper.
Název v anglickém jazyce
Substrate-assisted laser desorption inductively-coupled plasma mass spectrometry for determination of copper in myeloid leukemia cells
Popis výsledku anglicky
This work presents a detailed characterization of substrate-assisted laser desorption inductively coupled plasma mass spectrometry (SALD ICP-MS), a new approach in the determination of trace elements in submicrolitre volumes. SALD ICP-MS allows quantitative analysis of metals in liquid samples with defined volumes deposited onto an absorbing substrate due to complete sample desorption at relatively low laser power density. Analysis of model samples of Cu(II) showed a constant signal over a wide range oflaser power density, an independence of signal on desorption modes and a wide linear dynamic range. SALD ICP-MS with its limit of detection for copper below 26 fg in submicrolitre samples was successfully applied to investigate cytotoxic effects of disulfiram in human myeloid leukemia cells U937 depending on intracellular levels of copper.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F09%2F1025" target="_blank" >GA203/09/1025: Multidetekční platforma pro mikrokolonové separace proteinů a peptidů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
ISSN
0267-9477
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—