Determination of carbon in solidified sodium coolant usingnew ICP-OES methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F11%3A00050724" target="_blank" >RIV/00216224:14310/11:00050724 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of carbon in solidified sodium coolant usingnew ICP-OES methods
Popis výsledku v původním jazyce
New methods for the determination of carbon in sodium using laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and ICP-OES with pneumatic nebulisation (PN-ICP-OES) were developed. The determination was required for the study of the carbon dioxide reaction with molten sodium at high temperatures (300?600C). After exposition to CO2, the solidified sodium sample was subjected to direct solid analysis by LA-ICP-OES and to solution analysis. For the determination of carbon in the sodium sample surface layer by LA-ICP-OES, three different matrices containing sodium were tested (NaCl, NaF, and Na2B4O7 10H2O) as calibration pellets. The calibration dependences were improved using sodium as the internal standard. Average carboncontent in the sodium bulk sample was determined by PN-ICP-OES after the sample dissolution by water vapour.
Název v anglickém jazyce
Determination of carbon in solidified sodium coolant usingnew ICP-OES methods
Popis výsledku anglicky
New methods for the determination of carbon in sodium using laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and ICP-OES with pneumatic nebulisation (PN-ICP-OES) were developed. The determination was required for the study of the carbon dioxide reaction with molten sodium at high temperatures (300?600C). After exposition to CO2, the solidified sodium sample was subjected to direct solid analysis by LA-ICP-OES and to solution analysis. For the determination of carbon in the sodium sample surface layer by LA-ICP-OES, three different matrices containing sodium were tested (NaCl, NaF, and Na2B4O7 10H2O) as calibration pellets. The calibration dependences were improved using sodium as the internal standard. Average carboncontent in the sodium bulk sample was determined by PN-ICP-OES after the sample dissolution by water vapour.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2A-1TP1%2F067" target="_blank" >2A-1TP1/067: Výzkum technologií pro přenos vysokopotencionálního tepla z jaderného zdroje.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
0366-6352
e-ISSN
—
Svazek periodika
65
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
620-625
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—