Comparison of LA-ICP-MS and LA-ICP-OES for the analysis of some elements in fly ashes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F11%3A00055726" target="_blank" >RIV/00216224:14310/11:00055726 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2011/JA/c0ja00020e" target="_blank" >http://pubs.rsc.org/en/Content/ArticleLanding/2011/JA/c0ja00020e</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c0ja00020e" target="_blank" >10.1039/c0ja00020e</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of LA-ICP-MS and LA-ICP-OES for the analysis of some elements in fly ashes
Popis výsledku v původním jazyce
In this work quantitative analysis of minor and trace elements in fly ash by nanosecond laser ablation (LA)-ICP-MS and LA-ICP-OES was investigated in terms of detection limits and accuracy. Different binders and modifiers (silver or chromophores) were added to the fly ash powder to prepare mechanically stable pellets and improve sensitivity (signal to concentration ratio). Maleic acid was found to provide a higher degree of homogeneity between sensitivities across the different fly ashes tested. Ashes were from different origins: domestic waste incinerator or ashes from various coal-fired power plants. A calibration procedure using reference materials as standards was employed, the LAICP- MS analysis gave an acceptable accuracy (estimated from NIST 1633), better results were obtained using fused bead preparation.
Název v anglickém jazyce
Comparison of LA-ICP-MS and LA-ICP-OES for the analysis of some elements in fly ashes
Popis výsledku anglicky
In this work quantitative analysis of minor and trace elements in fly ash by nanosecond laser ablation (LA)-ICP-MS and LA-ICP-OES was investigated in terms of detection limits and accuracy. Different binders and modifiers (silver or chromophores) were added to the fly ash powder to prepare mechanically stable pellets and improve sensitivity (signal to concentration ratio). Maleic acid was found to provide a higher degree of homogeneity between sensitivities across the different fly ashes tested. Ashes were from different origins: domestic waste incinerator or ashes from various coal-fired power plants. A calibration procedure using reference materials as standards was employed, the LAICP- MS analysis gave an acceptable accuracy (estimated from NIST 1633), better results were obtained using fused bead preparation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Analytical Atomic Spectrometry
ISSN
0267-9477
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
443-449
Kód UT WoS článku
000286613700023
EID výsledku v databázi Scopus
—